11
Using the Optional Keypad Display Module (KDM)
1
—KDM Display Screen
2
—KDM Power On / Off Button
3
—Shift Button—used to access alternate functions on highlighted buttons
4
—SEND Button—Used to send new or edited parameter sets to the tool and controller
5
—Numerical / Alternate Function keypad
Parameter Set Terms
ANGLE CONTROL / TORQUE MONITOR—
Control strategy in which angle is the control parameter, but torque
is monitored.
ANGLE TARGET—
Desired value for angle rotation; measured from threshold torque value.
AUTO
-
SET—
Feature that allows manual entry of control parameters, but all others are determined by system defaults.
CYCLE COMPLETE—
Torque level that determines the completion of a fastening cycle.
THRESHOLD—
The torque value above which the system is,
“
in cycle
”
and data points are stored.
DOWNSHIFT TORQUE—
Torque level at which the spindle changes from free speed to downshift speed.
ERGO MODE—
Ramps the cut
-
off of power after reaching target torque, providing an ergonomic shutoff during a
hand
-
held tightening operation. (
Can negatively effect cpk calculations
)
HI LIMIT—
The upper control limit for torque and/or angle.
LO LIMIT—
The lower control limit for torque and/or angle. Must be set lower than target parameter. Any torque/angle low-
er than this value will be indicated by a yellow light and with a Lo Torque and/or Low Angle error on KDM.
RPM FREE—
Spindle output speed at the beginning of a tightening cycle, entered as a percentage of maximum tool speed.
RPM DOWN—
Spindle output speed after exceeding downshift torque; entered as a percentage of maximum tool speed.
SSTART—
(
Soft Start)
Speed of output spindle ramps up at a programmable rate to RPM free speed; allows the operator
or system to engage the socket onto the fastener in a more controlled fashion.
TARGET TORQUE—
Torque level which, when achieved, causes the power to the drive motor to be cut off.
TORQUE CONTROL—
Control strategy in which torque is the only control parameter.
TORQUE CONTROL / ANGLE MONITOR—
Control strategy in which torque is the control parameter, but rotational angle
is monitored. A valuable strategy for controlling torque while also checking for cross threaded or stripped fasteners.
4
3
2
1
5
Содержание iEC
Страница 1: ...AcraDyne iEC DC Tool Controllers User Guide...
Страница 35: ...35 Appendix B KDM Menu Structures Main Menu Structure Parameter Set up Menu...
Страница 36: ...36 APPENDIX B KDM Menu Structures Administration Menu...
Страница 45: ...45 Notes...
Страница 46: ...46 Notes...
Страница 47: ...47 Notes...