Chapter 5 BMC Configuration and Settings
42
Apollo User's Manual
The Sensor Readings page contains the following information.
Sensor Type (drop down menu)
This drop down menu allows you to select the type of sensor. The List
of sensors with the Sensor Name, Status and Current Reading will be
displayed in the list. If you select All Sensors, all the available sensor
details will appear else you can choose the sensor type that you
want to display in the list. Some examples of other sensors include
Temperature Sensors, Fan Sensors, and Voltage Sensors etc.
Select a particular sensor from the list. On the right hand side of the
screen you can view the Thresholds for this sensor.
Thresholds are of six types:
• Lower Non-Recoverable (LNR)
• Lower Critical (LC)
• Lower Non-Critical (LNC)
• Upper Non-Recoverable (UNR)
• Upper Critical (UC)
• Upper Non-Critical (UNC)
The threshold states could be Lower Non-critical - going low, Lower
Non-critical - going high, Lower Critical - going low, Lower Critical
- going high, Lower Non-recoverable - going low, Lower Non-
recoverable - going high, Upper Non-critical - going low, Upper Non-
critical - going high, Upper Critical - going low, Upper Critical - going
high, Upper Non-recoverable - going low, Upper Non-recoverable -
going high.
A graphical view of these events (Number of event logs vs.
Thresholds) can be viewed as shown in the Sensor Readings Page
screenshot.
Содержание apollo
Страница 1: ...Apollo Server MotherBoard User s Manual UM_Apollo_v 1_120716...
Страница 3: ...5 4 7 Maintenance Group 144 5 4 8 Firmware Update 153 Chapter 6 Technical Support 159 contents...
Страница 31: ...Chapter 5 BMC Configuration and Settings 25 Apollo User s Manual 2 Input IP address Set static IP...
Страница 32: ...Chapter 5 BMC Configuration and Settings 26 Apollo User s Manual 3 Input subnet mask address...