Servicing | 10
370607_2_0718
57 / 64
2. If fitted, switch off the On/Off-switch.
3. Disconnect the plug.
Prolonged decommissioning:
– Steps for decommissioning.
– Perform basic cleaning (see →Basic cleaning).
NOTICE
Material damage due to prolonged decommissioning.
▪ Do not expose the unit to any direct heat radiation.
▪ Do not place objects in or on the unit.
▪ Store the unit in a stable position (horizontal alignment).
9.2.2 Recommissioning
Recommissioning see commissioning →Commissioning.
9.3 Faults in operation
NOTICE
Material and property damage with alarm display.
▪ Move the goods to another device with the same product temperature class.
▪ Contact maintenance services immediately (see →Maintenance services).
Display of alarms:
There are different types of alarms that indicate faults in operation.
–
Display operating element:
see
Operating and display elements [
– Fault code
– Acoustic alarm (optional).
10 Servicing
Monitoring tasks by operating staff:
Monitoring tasks
Frequency
See →Chapter
Perfect condition of the unit
continuously
Intended use
Operation (use)
Foreign objects in the goods compart-
ment
continuously
Intended use
Operation (use)
Damaged glass element
continuously
Mechanical hazards
Operation (use)
Breakage of stored glass containers
continuously
Mechanical hazards
Operation (use)
Temperature
several times daily
Temperature display
Operation (use)
Correct loading of goods
continuously
Loading
Development of puddles in front of/un-
derneath the unit (defrosted water, flu-
ids from damaged packaging)
daily
Automatic defrost
Mechanical hazards
Contamination of the unit incl. glass
daily
Cleaning steps
Food waste and packaging waste
daily
Cleaning steps
Visual inspection of the area under the
air intake grille
daily
Cleaning steps
Floor (around the unit)
daily
Cleaning steps