5 Maintenance and Repair
64
Hydrostatic Implement Carrier
agria 5900 Bison
Hydraulic hoses
•
Check for leaks, damage and ageing after
200
operating hours, at least
yearly
.
•
Replace hydraulic hoses after
6 years
. Use
only new (not older than 2 years) genuine
Agria hydraulic hoses.
High-pressurized hydraulic oil can pene-
trate your skin and cause severe injuries.
Danger to life!
To avoid injuries, use suitable devices when
you try to locate leaks - specialized work-
shop!
Brake
•
Check smooth operation and efficiency of
brake pads and brake actuation after every
200
operating hours or at least yearly.
- agria-Service -
Wheel motors
•
Check for straightline driving at steering bar
neutral position every
200
operating hours.
- agria-Service -
Bar latching pin
Lubricate the lubricating nipple of the bar latch-
ing pin every now and then with bio lubricating
grease, at least
yearly
and after each cleaning
with a high-pressure cleaner.
Steering bar lock
After every
200
operating hours and after each
cleaning with a high-pressure cleaner coat at
both sides the bar lock rolls (A/8) for the bar
rollers with some bio lubricating grease.