Agilent U1251A/U1252A User’s and Service Guide
3
Safety Information
This meter is safety-certified in compliance with EN/IEC 61010-1:2001, UL 61010-1 Second Edition and CAN/CSA
22.2 61010-1 Second Edition, Category III 1000 V Overvoltage Protection, Pollution Degree II. Use with standard or
compatible test probes.
WA RN I N G
A WARNING notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if
not correctly performed or adhered to, could result in personal injury or death. Do not proceed beyond a
WARNING notice until the indicated conditions are fully understood and met.
A
CAUTION
notice denotes a hazard. It calls attention to an operating procedure, practice, or the like that, if not
correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed
beyond a
CAUTION
notice until the indicated conditions are fully understood and met.
Use the meter only as specified in this guide. Otherwise, the protection provided by the meter may be impaired.
Refer to the safety information below:
•
When working above 70V DC, 33 V AC RMS or 46.7 V peak, exercise caution – such range pose a shock
hazard.
•
Do not measure more than the rated voltage (as marked on the meter) between terminals, or between terminal
and earth ground.
•
Double-check the meter’s operation by measuring a known voltage.
•
For current measurement, turn off circuit power before connecting the meter to the circuit. Always place the
meter in series with the circuit.
•
When connecting probes, always connect the common test probe first. When disconnecting probes, always
disconnect the live test probe first.
•
Detach test probes from the meter before you open the battery cover.
•
Do not use the meter with the battery cover or part of the cover removed or loose.
•
Replace the battery as soon as the low battery indicator
flashes on screen. This is to avoid false readings,
which may lead to possible electric shock or personal injury.
•
Do not operate the product in an explosive atmosphere or in the presence of flammable gases or fumes.
Содержание U1251A
Страница 1: ...Agilent Technologies Agilent U1251A and U1252A Handheld Digital Multimeter User s and Service Guide...
Страница 34: ...34 Agilent U1251A U1252A User s and Service Guide 1 Getting Started Tutorial...
Страница 37: ...Making Measurements 2 Agilent U1251A U1252A User s and Service Guide 37 Figure 3 Measuring AC voltage MAX...
Страница 43: ...Making Measurements 2 Agilent U1251A U1252A User s and Service Guide 43 Figure 8 Measuring frequency Push MAX...
Страница 47: ...Making Measurements 2 Agilent U1251A U1252A User s and Service Guide 47 Figure 11 Conductance measurement MAX...
Страница 74: ...74 Agilent U1251A U1252A User s and Service Guide 3 Features and Functions Figure 26 Log review mode operation...
Страница 112: ...112 Agilent U1251A U1252A User s and Service Guide 5 Maintenance Figure 52 Battery charging procedures...
Страница 114: ...114 Agilent U1251A U1252A User s and Service Guide 5 Maintenance Figure 53 Fuse replacement Fuse 1 Fuse 2...
Страница 116: ...116 Agilent U1251A U1252A User s and Service Guide 5 Maintenance...
Страница 120: ...120 Agilent U1251A U1252A User s and Service Guide 6 Accessories...
Страница 156: ...156 Agilent U1251A U1252A User s and Service Guide 8 Specifications...