DIGITAL MULTIMETER

MODEL:    MS8233E 

Users Manual 

 

Содержание MS8233E

Страница 1: ...DIGITAL MULTIMETER MODEL MS8233E Users Manual ...

Страница 2: ...d double insulation The meter with holster that is giving the main body though downsized high resistance against the shock of a drop Protection provided by the instrument will be impaired if used in a manner not specified by the manufacturer This operating instruction covers information on safety and caution Please read relevant information carefully and observe all the warnings and note strictly ...

Страница 3: ...etermine that determine that the equipment is functioning correctly Note international Electrical Symbol Dangerous Voltage Ground AC Alternating current Warning see explain in manual DC Direct Current Double insulation AC or DC Fuse This product has been tested to the requirements ofC AN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same standard incorporating...

Страница 4: ...ntinuity and HOLD Press HOLD to enter and exit the hold mode in any mode That act with trigger MAX This key is act with trigger Press this key once the maximum value is holding Will displays MAX symbol in the LCD After pressing the key A D will keep working and the display value are always up dated and kept the maximum value NOTE The actual gained value is not the peak value This key is used contr...

Страница 5: ... Fahrenheit 9 µmVA mV V is unit of voltage µA mA A is unit of current 10 Indicate negative reading 6 Fig 2 LCD 4 Specification 4 1 General Specification Auto ranging DMM that full scale is 2000 counts Display 3 1 2 digit LCD display Over load protection Used the PTC protection circuit for Resistance temperature AC electric field detection function NCV function DATA HOLD function MAX value hold fun...

Страница 6: ...H Weight 140 x 67 x 30mm Approx 112g Accessary 1 K type temperature probe P3400 1pc 2 User s Manual 1pc 3 Test lead 1set 4 9V Battery 1pc 4 2 Electrical Specification at 23 5 75 RH 4 2 1 DC Voltage Range Resolution Accuracy 200mV 0 1mV 0 5 rdg 2dgt 2V 0 001V 20V 0 01V 200V 0 1V 600V 1V 0 8 rdg 2dgt 8 Over load protection SG Spark Gap used to protect that the voltage overred 1500V 4 2 2 AC Voltage ...

Страница 7: ...put terminal 4 2 7 AC Current 40Hz 400Hz Range Resolution Accuracy 200µA 0 1µA 1 5 rdg 4dgt 2000µA 1µA 20mA 0 01mA 200mA 0 1mA 10A 0 01A Over Load protection use the fuse F250mA H 250V at µA mA range and use the fuse F10A H 250V at 10A range 10 Max input current 250mA at mA input terminal and 10A at 10A input terminal 4 2 8 Temperature You can selecting Centi degree or Fahrenheit by FUNC key Range...

Страница 8: ... 12 5 2 Resistance measurement The resistance range are 200 0Ω 2 000KΩ 20 00KΩ 200 0KΩ 2 000MΩ 20 00MΩ To measure resistance connect the meter as follows 1 Insert the red test lead into the VΩ terminal and the black test lead into the COM terminal 2 Set the rotary switch to proper resistance range 3 Connect the test lead across with the object under testing The measured value will be show on the L...

Страница 9: ... Press the FUNC key to enter to the continuity mode The buzzer sound if the resistance of a circuit under test is less than 100Ω 14 NOTE Input signal level must be higher than 0 5V it is sensitivity 5 4 DC AC µA or mA measurement DC Current range is 200 0µA 2000µA and 20 00mA 200 0mA and then 10A range AC Current range is 200 0µA 2000µA and 20 00mA 200 0mA and then 10A range 1 Turn off power to th...

Страница 10: ...oltage in an electrical cricuit or equipment without touching them i e Non Contact Voltage detection NCV Detection against in wall outlet is possible The detecting position may be away about 20mm from the objet under check 16 6 Maintenance 6 1 Replacing the battery When meter display the battery must be replace to maintain normal operation Disconnect and remove all test probes from any live source...

Страница 11: ...y 1000v CATII or 600V CAT III 10 A or better warning TO AVOID ELECTRICAL SHOCK REMOVE TEST LEADS BEFORE OPENING BATTERY COVER RISQUE DE CHOC ÉLECTRIQUE RETIRER CORDONS DE MESURE D OUVERTURE AVANT couvercle des piles 6 4 Cleaning and Decontamination The meter can be cleaned with soft clean cloth to remove any oil grease or grim Do not use liquid solvent or detergent 17 ...