IDP-7 Dry Scroll Vacuum Pump 

2

DRAFT 1/19/17

EMC Warnings

EN 55011 Class A Warning

This is a Class A product. In a domestic environment this
product may cause radio interference in which case the
user may be required to take adequate measures.

FCC

This device complies with Part 15 of the FCC rules. Oper-
ation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this
device must accept any interference received, including
interference that may cause undesirable operation.

NOTE

The equipment has been tested and 
found to comply with the limits for a 
Class A digital device, pursuant to Part 
15 of the FCC rules. These limits are 
designed to provide reasonable protec-
tion against harmful interference when 
the equipment is operated in a commer-
cial environment. This equipment gen-
erated, uses, and can radiate radio 
frequency energy and, if not installed 
and used in accordance with the 
instruction manual, may cause harmful 
interference to radio communications. 
Operation of this equipment in a resi-
dential area is also likely to cause harm-
ful radio communications interference 
in which case the user will be required 
to correct the interference at his own 
expense.

Содержание IDP-7

Страница 1: ...D R A F T 1 1 9 1 7 Vacuum Products Division INSTRUCTION MANUAL IDP 7 Dry Scroll Vacuum Pump Manual No X3807 90009 Revision A January 2017...

Страница 2: ...D R A F T 1 1 9 1 7 Copyright 2017 Agilent Inc IDP 7 Dry Scroll Vacuum Pump Slo Blo and Littelfuse are registered trademarks of Littelfuse Inc...

Страница 3: ...luding representatives of Seller which are incon sistent or in conflict with the terms of this warranty shall not be binding upon Seller unless reduced to writing and approved by an officer of Seller...

Страница 4: ...nd Inspection 11 Installation 12 Safety 12 Startup 12 Electrical Connections 12 Start Current 14 Mechanical Connections 15 Operation 16 Cleaning the Pump 16 Startup Procedure 16 Shutdown Procedure 16...

Страница 5: ...and storing the pump the following environmental requirements should not be exceeded Preparation for Installation The pump is supplied in a special protective packing If this shows signs of damage whi...

Страница 6: ...irable operation NOTE The equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonabl...

Страница 7: ...must NOT be disposed of together with ordi nary domestic or industrial waste but must be sent to a differentiated waste collection system The end user is therefore invited to contact the supplier of...

Страница 8: ...erference that may cause undesired oper ation If this equipment does cause harmful interference to radio or television reception which can be determined by turn ing the equipment off and on the user i...

Страница 9: ...ences environnementales suivantes ne doivent pas tre d pass es Pr paration pour l installation La pompe est livr e dans un emballage protecteur sp cial Si elle manifeste des signes de dommages qui peu...

Страница 10: ...quer une op ration ind sirable REMARQUE L quipement a t test et d clar con forme aux limites d un dispositif num rique de Classe A selon la Partie 15 des r gles de la FCC Ces limites sont destin es f...

Страница 11: ...oit seulement tre allum e en utilisant le commutateur On Off La vanne d admission en option s ouvrira 30 secondes apr s le d marrage de la pompe Il n existe aucune instruction sp ciale pour l arr t de...

Страница 12: ...nisseur du dispositif maison m re ou revendeur pour mettre en uvre le processus de collecte et mise au rebut Pour en savoir plus consulter http www agilent com environment product index shtml AVERTIS...

Страница 13: ...AC below 230 VAC Ultimate pressure 20 mT at 60 Hz 30 mT at 50 Hz Inlet connection NW25 Exhaust connection NW16 Gas ballast Female 1 8 National Pipe Thread 20 micron sintered plug provided SAE 2 5 16 2...

Страница 14: ...IDP 7 Dry Scroll Vacuum Pump 10 D R A F T 1 1 9 1 7 Figure 1 Outline Drawing with Dimensions Figure 2 Pumping Speed Curves...

Страница 15: ...Cowling 9 Mounting Holes 4 through holes for 1 4 or M6 Hardware 10 Rear Cowling 11 KA40 Phillips PT hardware 6 12 On Off Switch 13 Fuse Holder and Voltage Changeover Tab 14 Power Connection IEC 320 15...

Страница 16: ...ire Install in an area that is not exposed to rain steam or excessive humidity They can cause electric shock short circuits and severe bodily injury Before reconfiguring the pump voltage or inspecting...

Страница 17: ...rent your product will draw An under sized cord will cause a drop in line voltage resulting in loss of power and overheating Table 2 IDP 7 Power Cord Selection Country Power Cord Specification Order E...

Страница 18: ...7 Start Current Table 3 lists the typical IDP 7 maximum starting current and duration Table 3 Typical IDP 7 Maximum Starting Current A Frequency High Voltage Range 100 V 120 V 127 V 200 V 230 V 240 V...

Страница 19: ...d to normal ambient humidity Gas ballast port 2 is used for high water vapor loads such as repetitively pumping out a volume exposed to excessive ambient humidity or pro cess gas loads with a high wat...

Страница 20: ...configured for the mains voltage to which the pump is connected See Electri cal Connections on page 12 Figure 6 ON OFF Power Switch 2 Switch the pump ON 3 If the pump is equipped with an optional inl...

Страница 21: ...llast plugged Replace breather vent Contact Agilent Solvent in pump Flush pump with air or dry nitrogen Install trap or filter Seals worn out Rebuild pump Poor conductance to pump Replumb with shorter...

Страница 22: ...mp periodically at atmosphere for a minute or two to flush it out For more information see Cleaning the Pump on page 16 Tip Seal Replacement The parts and tools required to replace tip seals include T...

Страница 23: ...Tip Seal onto the Orbiting Scroll item 9 3 Sequentially insert the seal from center to the outer edge of the scroll wall 4 Cut the Tip Seal about 1 8 3 mm from the groove end 5 Use the remaining Tip S...

Страница 24: ...e 2 Disassemble and repair as necessary The pump is now ready to return to service 1 Front Cowling Bolts M8 3 2 Exhaust Fitting NW16 3 Front Cowling 4 Frame Bolts M5 4 5 Scroll Housing 6 Main O ring P...

Страница 25: ...he core product e g inlet screens vent valves o Prior to shipment and if applicable for your product drain any oils or other liquids purge or flush all gasses and wipe off any excess residue o If orde...

Страница 26: ...15 business days Failure to do so or returning a non rebuildable part crashed will result in an invoice for the non returned non rebuildable part o Returns for credit toward the purchase of new or ref...

Страница 27: ...e Chemical name Chemical Symbol CAS Number Toxic YES NO Harmful YES NO Corrosive YES NO Reactive YES NO Flammable YES NO Explosive YES NO Radioactive YES NO Biological YES NO Oxidizing YES NO Sensitiz...

Отзывы: