Warranty

Products manufactured by Seller are warranted against
defects in materials and workmanship for twelve (12)
months from date of shipment thereof to Customer, and
Seller's liability under valid warranty claims is limited, at
the option of Seller, to repair, to replace, or refund of an
equitable portion of the purchase price of the Product.
Items expendable in normal use are not covered by this
warranty. All warranty replacement or repair of parts shall
be limited to equipment malfunctions which, in the sole
opinion of Seller, are due or traceable to defects in origi-
nal materials or workmanship. All obligations of Seller
under this warranty shall cease in the event of abuse,
accident, alteration, misuse, or neglect of the equipment.
In-warranty repaired or replaced parts are warranted only
for the remaining unexpired portion of the original war-
ranty period applicable to the repaired or replaced parts.
After expiration of the applicable warranty period, Cus-
tomer shall be charged at the then current prices for parts,
labor, and transportation.

Reasonable care must be used to avoid hazards. Seller
expressly disclaims responsibility for loss or damage
caused by use of its Products other than in accordance
with proper operating procedures.

Except as stated herein, Seller makes no warranty,
expressed or implied (either in fact or by operation of
law), statutory or otherwise; and, except as stated herein,
Seller shall have no liability under any warranty,
expressed or implied (either in fact or by operation of
law), statutory or otherwise. Statements made by any per-
son, including representatives of Seller, which are incon-
sistent or in conflict with the terms of this warranty shall
not be binding upon Seller unless reduced to writing and
approved by an officer of Seller.

Warranty Replacement 
and Adjustment

All claims under warranty must be made promptly after
occurrence of circumstances giving rise thereto, and must
be received within the applicable warranty period by
Seller or its authorized representative. Such claims should
include the Product serial number, the date of shipment,
and a full description of the circumstances giving rise to
the claim. Before any Products are returned for repair
and/or adjustment, written authorization from Seller or its
authorized representative for the return and instructions
as to how and where these Products should be returned
must be obtained. Any Product returned to Seller for
examination shall be prepaid via the means of transporta-
tion indicated as acceptable by Seller. Seller reserves the
right to reject any warranty claim not promptly reported
and any warranty claim on any item that has been altered
or has been returned by non-acceptable means of trans-
portation. When any Product is returned for examination
and inspection, or for any other reason, Customer shall be
responsible for all damage resulting from improper pack-
ing or handling, and for loss in transit, notwithstanding
any defect or non-conformity in the Product. In all cases,
Seller has the sole responsibility for determining the cause
and nature of failure, and Seller's determination with
regard thereto shall be final.

If it is found that Seller's Product has been returned with-
out cause and is still serviceable, Customer will be noti-
fied and the Product returned at the Customer's expense;
in addition, a charge for testing and examination may be
made on Products so returned.

Содержание IDP-7

Страница 1: ...D R A F T 1 1 9 1 7 Vacuum Products Division INSTRUCTION MANUAL IDP 7 Dry Scroll Vacuum Pump Manual No X3807 90009 Revision A January 2017...

Страница 2: ...D R A F T 1 1 9 1 7 Copyright 2017 Agilent Inc IDP 7 Dry Scroll Vacuum Pump Slo Blo and Littelfuse are registered trademarks of Littelfuse Inc...

Страница 3: ...luding representatives of Seller which are incon sistent or in conflict with the terms of this warranty shall not be binding upon Seller unless reduced to writing and approved by an officer of Seller...

Страница 4: ...nd Inspection 11 Installation 12 Safety 12 Startup 12 Electrical Connections 12 Start Current 14 Mechanical Connections 15 Operation 16 Cleaning the Pump 16 Startup Procedure 16 Shutdown Procedure 16...

Страница 5: ...and storing the pump the following environmental requirements should not be exceeded Preparation for Installation The pump is supplied in a special protective packing If this shows signs of damage whi...

Страница 6: ...irable operation NOTE The equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonabl...

Страница 7: ...must NOT be disposed of together with ordi nary domestic or industrial waste but must be sent to a differentiated waste collection system The end user is therefore invited to contact the supplier of...

Страница 8: ...erference that may cause undesired oper ation If this equipment does cause harmful interference to radio or television reception which can be determined by turn ing the equipment off and on the user i...

Страница 9: ...ences environnementales suivantes ne doivent pas tre d pass es Pr paration pour l installation La pompe est livr e dans un emballage protecteur sp cial Si elle manifeste des signes de dommages qui peu...

Страница 10: ...quer une op ration ind sirable REMARQUE L quipement a t test et d clar con forme aux limites d un dispositif num rique de Classe A selon la Partie 15 des r gles de la FCC Ces limites sont destin es f...

Страница 11: ...oit seulement tre allum e en utilisant le commutateur On Off La vanne d admission en option s ouvrira 30 secondes apr s le d marrage de la pompe Il n existe aucune instruction sp ciale pour l arr t de...

Страница 12: ...nisseur du dispositif maison m re ou revendeur pour mettre en uvre le processus de collecte et mise au rebut Pour en savoir plus consulter http www agilent com environment product index shtml AVERTIS...

Страница 13: ...AC below 230 VAC Ultimate pressure 20 mT at 60 Hz 30 mT at 50 Hz Inlet connection NW25 Exhaust connection NW16 Gas ballast Female 1 8 National Pipe Thread 20 micron sintered plug provided SAE 2 5 16 2...

Страница 14: ...IDP 7 Dry Scroll Vacuum Pump 10 D R A F T 1 1 9 1 7 Figure 1 Outline Drawing with Dimensions Figure 2 Pumping Speed Curves...

Страница 15: ...Cowling 9 Mounting Holes 4 through holes for 1 4 or M6 Hardware 10 Rear Cowling 11 KA40 Phillips PT hardware 6 12 On Off Switch 13 Fuse Holder and Voltage Changeover Tab 14 Power Connection IEC 320 15...

Страница 16: ...ire Install in an area that is not exposed to rain steam or excessive humidity They can cause electric shock short circuits and severe bodily injury Before reconfiguring the pump voltage or inspecting...

Страница 17: ...rent your product will draw An under sized cord will cause a drop in line voltage resulting in loss of power and overheating Table 2 IDP 7 Power Cord Selection Country Power Cord Specification Order E...

Страница 18: ...7 Start Current Table 3 lists the typical IDP 7 maximum starting current and duration Table 3 Typical IDP 7 Maximum Starting Current A Frequency High Voltage Range 100 V 120 V 127 V 200 V 230 V 240 V...

Страница 19: ...d to normal ambient humidity Gas ballast port 2 is used for high water vapor loads such as repetitively pumping out a volume exposed to excessive ambient humidity or pro cess gas loads with a high wat...

Страница 20: ...configured for the mains voltage to which the pump is connected See Electri cal Connections on page 12 Figure 6 ON OFF Power Switch 2 Switch the pump ON 3 If the pump is equipped with an optional inl...

Страница 21: ...llast plugged Replace breather vent Contact Agilent Solvent in pump Flush pump with air or dry nitrogen Install trap or filter Seals worn out Rebuild pump Poor conductance to pump Replumb with shorter...

Страница 22: ...mp periodically at atmosphere for a minute or two to flush it out For more information see Cleaning the Pump on page 16 Tip Seal Replacement The parts and tools required to replace tip seals include T...

Страница 23: ...Tip Seal onto the Orbiting Scroll item 9 3 Sequentially insert the seal from center to the outer edge of the scroll wall 4 Cut the Tip Seal about 1 8 3 mm from the groove end 5 Use the remaining Tip S...

Страница 24: ...e 2 Disassemble and repair as necessary The pump is now ready to return to service 1 Front Cowling Bolts M8 3 2 Exhaust Fitting NW16 3 Front Cowling 4 Frame Bolts M5 4 5 Scroll Housing 6 Main O ring P...

Страница 25: ...he core product e g inlet screens vent valves o Prior to shipment and if applicable for your product drain any oils or other liquids purge or flush all gasses and wipe off any excess residue o If orde...

Страница 26: ...15 business days Failure to do so or returning a non rebuildable part crashed will result in an invoice for the non returned non rebuildable part o Returns for credit toward the purchase of new or ref...

Страница 27: ...e Chemical name Chemical Symbol CAS Number Toxic YES NO Harmful YES NO Corrosive YES NO Reactive YES NO Flammable YES NO Explosive YES NO Radioactive YES NO Biological YES NO Oxidizing YES NO Sensitiz...