Example: Digital
Output Configuration
Figure 3-4 shows channel 00 configured for digital output operation. When
the channel 00 relay is open (NC connected to C), point 1 is at + V and point
2 is at 0 V. When the channel 00 relay is closed (NO connected to C), points
1 and 2 are both at 0 V. (This configuration is useful for 24V or 48V control
logic, since this type of application cannot be met with the configuration
shown in Chapter 2, Figure 2-5.) To close channel 00, execute:
CLOS (@100)
Close channel 00 relay (connect
NO to C). 1 is the card number and
00 is the channel number.
To open channel 00, use
OPEN (@100)
.
Figure 3-4. Example: Digital Output Configuration
Chapter 3
Using the Agilent E1364A Form C Switch 29
Содержание E1364A
Страница 2: ......
Страница 6: ...Notes 4 Agilent E1364A Switch Module Table of Contents ...
Страница 10: ...Notes 8 Agilent E1364A 16 Channel Form C Switch User s Manual ...
Страница 11: ...Notes Agilent E1364A 16 Channel Form C Switch User s Manual 9 ...
Страница 12: ...Notes 10 Agilent E1364A 16 Channel Form C Switch User s Manual ...
Страница 18: ...16 Getting Started with the Agilent E1364A Chapter 1 ...
Страница 21: ...Figure 2 2 Wiring the Form C Switch Terminal Block Chapter 2 Configuring the Agilent E1364A Form C Switch 19 ...
Страница 70: ...68 Agilent E1364A Form C Switch Registers Appendix B ...
Страница 72: ...70 Agilent E1364A Form C Switch Error Messages Appendix C ...
Страница 76: ...74 Agilent E1364A 16 Channel Form C Switch Index ...