Example: Relay
Control Configuration
Figure 2-4 shows one way to control external relays using the +5V/NO
source. For this example, channel 15 is dedicated to provide the +5V source
to external relays 1 and 2. When the Form C Switch channel 00 relay is
open, external relay 1 is connected to ground and +5V is applied to external
relay 1. When the Form C Switch channel 00 is closed, external relay 2 is
connected to ground and +5V is applied to external relay 2.
Figure 2-4. Example: Relay Control Configuration
Chapter 2
Configuring the Agilent E1364A Form C Switch 21