Set Up Your System
3
Agilent E6474A User’s Guide
41
Figure 19
External GPS - Placer 455
Example 3 - Placer 455 with differential GPS
Refer to
Figure 20
on page 42.
1
Connect the RTCM port of the Trimble- supplied
communications cable to the differential GPS receiver,
using the RS- 232 null modem cable included with the
system. Connect the remaining port of the
Trimble- supplied communications cable to the MDT/RTCM
port of the Trimble Placer GPS 455 unit.
2
Connect the digital port of the adapter box to the Digital
IO port of the Trimble Placer GPS 455 unit, using the
RS- 232 cable.
3
Connect the MDT/RTCM port of the adapter box to the
MDT port of the Trimble- supplied communications “T”
cable, connected to the Differential, using the RS- 232
cable.