Programming
Examples
1505
"Change
Source
Power
while
Observing
Trace
AND
Power
Meter."
1506
LOCAL
@Nwa
1507
RETURN
1508
!
1509
Example30:
!
Receiver
Power
Cal
*********************
1510
1511
"Example
30,
Receiver
Power
Cal"
1512
"A
Valid
2-20
Ghz
Test
Port
Power
Flatness
Cal
(Example
29)"
1513
"And
8510C
Firmware
>=
Rev.C.07.00
Required."
1514
INPUT
"Skip
this
example?
(Enter
Y
or
N)",Input$
1515
IF
UPC$(Input$)<>"N"
THEN
RETURN
1516
DISP
"Initializing
System"
1517
OUTPUT
@Nwa;"PRES;
POIN101;
STEP;
STAR
2GHZ;
STOP
20GHZ;
MARK1;
POWE
-5;
USER1;"
1518
INPUT
"Connect
Thru
between
Port
1
and
Port
2
for
Receiver
Cal
(Press
Return)",Input$
1519
OUTPUT
@Nwa;"CALRCVR;
RCVO;
RCVI;
SAVR;
CALS2;"
1520
OUTPUT
@Nwa;"CHAN2;
USER2;
SPLI;
MENUSTIM;
SOFT1;
SOFT8"
1521
LOCAL
@Nwa
1522
"Calibrated
DUT
Input
and
Output
Power
now
displayed
(dbm)."
1523
INPUT
"Turn
Flatness
On
if
leveled
test
port
power
is
desired
(Press
Return)",Input$
1524
OUTPUT
@Nwa;"MARK1"
1525
LOCAL
@Nwa
1526
INPUT
"Set
Marker
to
desired
Frequency
of
Measurement
for
Power
Domain
(Press
Return)",Input$
1527
OUTPUT
@Nwa;"POWD;"
1528
LOCAL
@Nwa
1529
"Power
Domain
-
Stimulus
Start,
Stop
keys
set
Power"
1530
"Next
Pt
Higher
/
Lower
keys
select
next
Calibrated
Frequency
of
Measurement"
1531
RETURN
1532
!
1533
Example31:
!
Cal
Sets
LOAD
and
STORE
Operations
*****************
1534
1535
"Example
31,
Cal
Set
LOAD
&
STORE"
1536
"8510C
Firmware
>=
Rev.C.07.00
Required."
1537
"Requires
any
valid
calibration
in
CAL
SET
1
and
a
disk
in
the
internal
drive"
1538
INPUT
"Skip
this
example?
(Enter
Y
or
N)",Input$
1539
IF
UPC$(Input$)<>"N"
THEN
RETURN
1540
DISP
"Initializing
System"
1541
OUTPUT
@Nwa;"CORROFF"
1542
OUTPUT
@Nwa;"STOR;CALS1;DISF;""ABC"""
1543
"'FILE
""CS_ABS""
STORED
TO
DISC'
now
displayed
on
8510."
1544
INPUT
"To
continue
with
LOAD
operation;
(Press
Return)",Input$
1545
OUTPUT
@Nwa;"LOAD;CALS1;DISF;""ABC"""
1546
"'FILE
""CS_ABS""
LOADED
FROM
DISC'
now
displayed
on
8510."
1547
RETURN
1548
!
****************
1549
!
End
of
Examples.
The
following
subroutines
are
used
by
the
examples:
1550
!
****************
1551
!
1552
Run_mode:
!
1553
INPUT
"Run
ALL
Examples
or
a
SINGLE
Example?
(Enter
A
or
S)",Input$
1554
IF
UPC$(Input$)="A"
THEN
1555
RETURN
1556
ELSE
1557
Choice:
!
1558
INPUT
"Enter
the
number
of
the
example
you
wish
to
run.
(1
to
31
or
0
to
Quit)",Input$
1559
IF
Input$="0"
THEN
1560
LOCAL
@Nwa
1561
STOP
1562
END
IF
GPIB
Programming
13-67
Содержание 8510C
Страница 7: ...vii ...
Страница 29: ......
Страница 61: ......
Страница 73: ...Network Analyzer System Description Figure 3 7 Recommended Typical Test Setups 3 12 Principles of Operation ...
Страница 98: ...DISPLAY Functions Figure 4 9 Display Menu Showing Trace Memory Locations Menu Measurement Controls 4 19 ...
Страница 105: ...FORMAT Functions Figure 4 12 Format Function Block and Format Menu 4 26 Measurement Controls ...
Страница 106: ...FORMAT Functions Figure 4 13 Format Selections 1 of 2 Measurement Controls 4 27 ...
Страница 107: ...FORMAT Functions Figure 4 14 Format Selections 2 of 2 4 28 Measurement Controls ...
Страница 122: ...PARAMETER Functions Figure 4 25 Redefine Parameter Menu Structure Measurement Controls 4 43 ...
Страница 175: ......
Страница 203: ......
Страница 223: ...Measurement Calibration Figure 8 2 Cal Type Selections 8 8 Calibrating for System Measurements ...
Страница 267: ...Figure 9 14 Typical Group Delay and Deviation from Ideal Phase Displays 9 14 Transmission Measurements ...
Страница 273: ......
Страница 297: ......
Страница 305: ......
Страница 391: ......