Figure
9-6.
Measuring
Minimum
and
Maximum
Insertion
Loss
Making
Insertion
Phase
Measurement
This
sequence
lists
the
steps
for
a
t
ypical
insertion
phase
measuremen
t.
1.
P
erform
appropriate
S
21
or
S
12
measuremen
t
calibration.
2.
Connect
the
DUT.
3.
Select
4
PHASE
5.
4.
Press
4
MARKER
5
and
read
insertion
phase
(degrees).
Figure
9-7
sho
ws
a
bandpass
lter
insertion
phase
display
using
the
4
PHASE
5
format.
The
measuremen
t
range
is
+180
degrees
to
0180
degrees,
and
the
v
ertical
line
represen
ts
the
transition
b et
w
een
these
t
w
o
v
alues.
Th
us,
the
trace
b et
w
een
an
y
t
w
o
of
these
transitions
represen
ts
360
degrees
of
phase
shift.
T
o
illustrate
the
display
format,
determine
the
total
phase
shift
for
the
selected
sw
eep
width
as
follo
ws:
1.
P
osition
the
marker
as
far
to
the
left
as
p ossible
and
note
the
phase
reading.
2.
Determine
the
n
um
b er
of
degrees
b efore
the
rst
transition.
3.
Coun
t
the
second
and
follo wing
transition
traces
and
m
ultiply
b
y
360.
4.
No
w
determine
the
n
um
b er
of
degrees
from
the
last
transition
trace
to
the
right
edge
of
the
screen.
The
sum
of
these
n
um
b ers
is
the
total
phase
shift
o
v
er
the
frequency
sw
eep.
F
or
example,
in
Figure
9-7:
TOT
AL
PHASE
SHIFT
=
(49.313+180)
+
3(360)
+
40
=
1349.3
When
the
transmitted
signal
is
b elow
the
noise
o or
for
insertion
phase
measuremen
ts,
the
LCD/CR
T
trace
usually
b ecomes
random.
9-8
Transmission
Measurements
Содержание 8510C
Страница 7: ...vii ...
Страница 29: ......
Страница 61: ......
Страница 73: ...Network Analyzer System Description Figure 3 7 Recommended Typical Test Setups 3 12 Principles of Operation ...
Страница 98: ...DISPLAY Functions Figure 4 9 Display Menu Showing Trace Memory Locations Menu Measurement Controls 4 19 ...
Страница 105: ...FORMAT Functions Figure 4 12 Format Function Block and Format Menu 4 26 Measurement Controls ...
Страница 106: ...FORMAT Functions Figure 4 13 Format Selections 1 of 2 Measurement Controls 4 27 ...
Страница 107: ...FORMAT Functions Figure 4 14 Format Selections 2 of 2 4 28 Measurement Controls ...
Страница 122: ...PARAMETER Functions Figure 4 25 Redefine Parameter Menu Structure Measurement Controls 4 43 ...
Страница 175: ......
Страница 203: ......
Страница 223: ...Measurement Calibration Figure 8 2 Cal Type Selections 8 8 Calibrating for System Measurements ...
Страница 267: ...Figure 9 14 Typical Group Delay and Deviation from Ideal Phase Displays 9 14 Transmission Measurements ...
Страница 273: ......
Страница 297: ......
Страница 305: ......
Страница 391: ......