16
– 66
Operating instructions EN
◼
SE-24
◼
01.06.2022
◼
V1.5
Avoiding accidents, bodily injuries and/or damage to property:
CAUTION
Additionally secure vertical axes against dropping or lowering after
switching off the motor, such as by:
▪
mechanical interlocking of the vertical axis,
▪
external braking/ catching/ clamping device or
▪
sufficient weight balancing of the axis.
The motor brake installed or an external motor brake controlled by
the drive control unit alone is not suitable for personnel safety!
CAUTION
Render the electrical equipment free of voltage via the main switch
and secure it against being switched on again, wait until the
intermediate circuit has been discharged during:
▪
maintenance work and repairs
▪
cleaning work
▪
long operational downtimes
Before carrying out any maintenance work, it must be ensured that
the power supply has been switched off, locked and that the
intermediate circuit has been discharged.
NOTE
It must also be ensured that the external voltage supply of the
controller (24 V) is switched off.
NOTE
The intermediate circuit or the mains voltage must always be
switched off before the 24V voltage supply of the controller is
switched off.