Operating instructions EN
◼
SE-24
◼
01.06.2022
◼
V1.5
31
–66
7.1.2 Input and output connections [X2]
Figure 5: View of the connection [X2]
7.1.2.1 Type on device [X2]
▪
Phoenix Contact: 12 pole sensor-/actuator flush-type plug,
SACC-DSI-M12MS-12CON-M16/0,5 Phoenix Contact No.1419700
7.1.2.2 Mating plug [X2]
▪
I/O cable SE-24, 5m, Afag No. 50312913
7.1.2.3 Pin assignment of the I/O cable
Pin
No.
Designation
Colour assignment
1
drive_enable/fault_reset
brown
2
start/stop_ref
blue
3
start/stop_move
white
4
reserve
green
5
pos_nr_bit0
pink
6
pos_nr_bit1
yellow
7
pos_nr_bit2
black
8
pos_nr_bit3
grey
9
ready
red
10
drive_enable_ok
violet
11
ref_valid
grey-pink
12
move_ok
red-blue
For the functional description of the inputs and outputs please see the document:
SE-24 IO Manual