Operating instructions EN
◼
SE-24
◼
01.06.2022
◼
V1.5
33
–66
NOTE
PROFIBUS cabling
Owing to the very high possible baud rates, we recommend the use
of the standardized cables and connectors exclusively. These are, to
an extent, equipped with additional diagnosis options and in case of
a fault, simplify the fast analysis of the fieldbus hardware.
When constructing the PROFIBUS network, follow the advice of the
current literature or the following information and instructions without
fail, to get a stable and fault-free system. In case of cabling not
having been done properly, faults can occur on the PROFIBUS
during operation, which can result in the servo controller getting
switched off with an error message, for reasons of safety.
7.1.4 Bus cable for PROFIBUS
The following cables of the company Phoenix Contact should be used for the Profibus
connection:
Bus system cable, PROFIBUS, 2 pole, PUR halogen-free, violet RAL 4001, shielded,
straight M12-SPEEDCON plug, b-coded, on straight M12-SPEEDCON socket, b-
coded
Phoenix Contact Profibus cable
PROFIBUS cable
Order No.
Length in m
1518106
0,3
1518119
0,5
1518122
1
1518135
2
1518148
5
1518151
10
1518164
15
Содержание 50315434
Страница 1: ...Servo Controller SE 24 Operating Instructions Operating manual Copyright by Afag Automation AG ...
Страница 47: ...Operating instructions EN SE 24 01 06 2022 V1 5 47 66 Figure 17 Example of a circuit diagram of the SE 24 I O ...
Страница 65: ...Operating instructions EN SE 24 01 06 2022 V1 5 65 66 ...