Operating instructions EN
◼
SE-24
◼
01.06.2022
◼
V1.5
57
–66
Error no.
[decimal]
Error no.
[hex]
Error name
Description
CANopen
error code
-1000
0xFC18
ERR_FieldUnderVoltage
Power voltage (Up) is too low
0x3220
-1001
0xFC17
ERR_FieldOverVoltage
Power voltage (Up) is too high
0x3210
-1002
0xFC16
ERR_MainsUnderVoltage
Electronics voltage (Ue) is too low
0x3120
-1003
0xFC15
ERR_MainsOverVoltage
Electronics voltage (Ue) is too high
0x3110
-1020
0xFC04
ERR_DeviceOverTemperature
Overtemperature of the device
0x4210
-1021
0xFC03
ERR_HeatSinkOverTemperature
Overtemperature of end stage
0x4310
-1060
0xFBDC
ERR_MotShortCircuit
Short-circuit
(motor-motor, motor-GND, motor-power)
0x2130
-1061
0xFBDB
ERR_MotOverCurrent
Overcurrent
-
-1078
0xFBCA
ERR_Enc_Failed
Encoder error
-
Regv errors
-3010
0xF43E
ERR_Blockage
The motor was blocked
-
Regp errors
-4000
0xF060
ERR_Regp_FollowingError
Permissible servo lag was exceeded
0x8611
Homing errors
-4200
0xF43E
ERR_Home_UnknownMethod
Unknown referencing method
-