TECHNOPLAT CS/CW
TECHNOPLAT CS/CW TP
|
Important
In the event of heavy use increase the inspection frequency by halving the maintenance intervals.
Heavy duty use definition:
‒
Operating temperature
<10 °C
.
‒
Number of packing
>50 /
per day.
‒
Dusty environment.
7.3. LUBRICATION POINT DIAGRAM
The following diagram shows the main components and the frequency of the lubrication interventions.
Symbol and Description
A -
Every
200
hours or
5000
cycles.
Smear with grease.
Check lubricant level.
Do not top-up and/or replace the lubricant in reduction gears and gearmotors lubricated for
life.
Keep to the recommended lubrication frequency to get top machine performances and a longer
operating life.
Use lubricants (oils or grease) recommended by the manufacturer or with similar chemical-
physical features.
7.4. LUBRICANTS TABLE
The table below specifies the lubricants recommended by the Manufacturer for each component and/or area of
the machine.
Use lubricants (oils or grease) recommended by the manufacturer or with similar chemical-
physical features.
Lubricant specifications
68/79