62
Chapter 2
www.aerotech.com
2.6.4. Digital Inputs 8-11 (J205)
The digital inputs are opto-isolated and may be connected to current sourcing or current sinking devices, as
shown in
and
. These inputs are designed to connect to other ground-referenced
circuits and are not intended for high-voltage isolation.
The opto-isolator's common connections can be directly connected to the drive's power supply; however,
doing so will effectively defeat the isolation and will reduce noise immunity.
Table 2-29:
Digital Input Specifications
Input Voltage
Approximate Input Current
Turn On Time
Turn Off Time
+5 V
1 mA
200 usec
2000 usec
+24 V
6 mA
4 usec
1500 usec
Table 2-30:
Digital Input Pins on the Auxiliary I/O Connector (J205)
Pin#
Description
In/Out/Bi
17
Digital Input 8 / CCW EOT Input
(1)
Input
18
Digital Input 9 / CW EOT Input
(1)
Input
24
Input Common
-
25
Digital Input 10 / Home Input
(1)
Input
26
Digital Input 11
Input
(1) Software configured option
Ndrive HPe 50/75/100
Installation and Configuration
Содержание Ndrive HPe 100
Страница 1: ...Revision 4 09 00 Ndrive HPe 50 75 100 Hardware Manual ...
Страница 14: ...Ndrive HPe 50 75 100 Quick Installation Guide 14 www aerotech com This page intentionally left blank ...
Страница 24: ...Ndrive HPe 50 75 100 Introduction 24 Chapter 1 www aerotech com This page intentionally left blank ...
Страница 59: ...Installation and Configuration Ndrive HPe 50 75 100 Figure 2 27 PSO Interface www aerotech com Chapter 2 59 ...
Страница 85: ... IO Expansion Board Ndrive HPe 50 75 100 Figure 3 9 Digital Opto Isolated Inputs www aerotech com Chapter 3 85 ...
Страница 106: ...106 Chapter 6 www aerotech com Ndrive HPe 50 75 100 Maintenance This page intentionally left blank ...
Страница 110: ...Ndrive HPe 50 75 100 Revision History 110 Appendix B www aerotech com This page intentionally left blank ...