BA Intellidrive User’s Manual
Communication and Commands
Version 1.4
Aerotech, Inc.
3-23
3.5.
BAI Motion and Program Commands
This section covers the programming commands used by the BAI. The programming
commands alphabetically listed in Table 3-10 can be used in a program or remote mode
by adding the letter "I" to the front of the command.
Table 3-10.
Motion Commands
Command
Function
AC
Set Acceleration
CL
Clear Limit
CS
Conditional gosub
CT
Conditional goto
DI
Disable amplifier
DW
Dwell for x milliseconds
EN
Enable amplifier
FA
Fault Acknowledge
FR
Freerun
GA
Set loop gains
GS
Goto subroutine
GT
Goto label
HO
Home an axis
IN
Point-to-point move
IT
Wait for input to change
LB
Program label
LE/LS
Loop ending Loop starting
LD
Load position register
MC
Motor commutate
OT
Change output
PM
Print message
PR AB
Absolute mode
PR IN
Incremental mode
PS
Program stop
RA
Set the ramp time
RG
Register function
RT
Run teach program
SR
Return from subroutine
WM
Wait Move
WA
Wait for move to finish