Technical Details
BA Intellidrive User’s Manual
7-16
Aerotech, Inc.
Version 1.4
Figure 7-13.
Wiring to Minimize EMI and Capacitive Coupling
Figure 7-14.
Wiring to Minimize EMI and Capacitive Coupling (BAI 50)
B
Earth Ground
BAI
AMPLIFIER
Grounding
Screw
GND
A
C
Shield
Twisted Together
Case Ground
Motor
One toriod (ferrite) around the three motor leads
(two for brush motors). There should be 10 turns
for 16 AWG wire and 7 turns for 14 AWG wire.
Use a Ferroxocube 500T600-3C81 core or
equivalent.
This configuration is especially important if the BAI amplifier is operating at DC bus voltages of 160 VDC or 320 VDC (e.g., 115 VAC or 230 VAC input power).
B
Earth Ground
BAI
AMPLIFIER
Grounding
Screw
GND
A
C
Shield
Twisted Together
Case Ground
Motor
One toriod (ferrite) around the three motor leads
(two for brush motors). There should be 10 turns
for 16 AWG wire and 7 turns for 14 AWG wire.
Use a Ferroxocube 500T600-3C81 core or
equivalent.
This configuration is especially important if the BAI amplifier is operating at DC bus voltages of 160 VDC or 320 VDC (e.g., 115 VAC or 230 VAC input power).