BA Intellidrive User’s Manual
Parameters
Version 1.4
Aerotech, Inc.
4-15
Requires a reset (CTRL-D) before taking effect.
Table 4-23.
Settings for Operating Mode PRM:20
PRM20
Settings
Default Value
4
Maximum Value
5
Minimum Value
1
Type
Long (32bit)
Units
-
4.2.21. PRM:22 Position Save
When set, the last commanded position is saved to the flash memory at the end of the
move. Due to the save, there may be a delay between the end of one move and the start of
the next move. Refer to Table 4-24 for parameter settings.
Table 4-24.
Settings for Position Save PRM:22
PRM:22
Settings
Default Value
0 (position is not saved)
Maximum Value
1
Minimum Value
0
Type
Long (32bit)
Units
-
4.2.22. PRM:23 Reload Saved Position on Power-Up
When set, this parameter reloads the position feedback register with the saved value. The
saved position can be found in PRM:24. Refer to Table 4-25 for parameter settings.
Table 4-25.
Settings for PRM:23
PRM:23
Settings
Default Value
0 (position is not reloaded)
Maximum Value
1
Minimum Value
0
Type
Long (32bit)
Units
-