Parameters
BA Intellidrive User’s Manual
4-38
Aerotech, Inc.
Version 1.4
4.5.9. PRM:209 Clock/Direction Multiplier
This parameter replaces PRM:19 and allows fractional scaling of the clock input pulses
when the BAI is operating in clock/direction mode. Refer to Table 4-85 for parameter
settings.
Table 4-85.
Settings for Clock/Direction Multiplier PRM:209
PRM:209
Settings
Default Value
1
Maximum Value
1000
Minimum Value
.001
Type
Float
Units
-
4.5.10. PRM:210 Acceleration
This parameter is used to define the acceleration. It is scaled by the user defined scale
factor in PRM:200. If the acceleration is zero, then the ramp time is used to calculate the
acceleration. Refer to Table 4-86 for parameter settings.
Table 4-86.
Settings for Acceleration
PRM:210
Settings
Default Value
0
Maximum Value
5.1x10
8
Minimum Value
0
Type
Float
Units
User units/sec
2
∇
∇
∇