Hardware Reference Guide
83
P
RODUCT
O
VERVIEW
Console Port
A male DB-9 serial port to which you can make a console connection
using an RS-232 (or "null modem") cable. The pin assignments are the
same as those on the HiveManager and on the HiveAP (see
The management station from which you make a serial connection to
the HiveManager must have a VT100 emulation program, such as Tera
Term Pro
©
(a free terminal emulator) or Hilgraeve Hyperterminal
®
(provided with Windows
®
operating systems). The following are the
serial connection settings: bits per second: 9600, data bits: 8, parity:
none, stop bits: 1, flow control: none. The default login name is
admin
and the password is
aerohive
. After making a connection, you can
access the Linux operating system.
MGT and LAN Ethernet Ports
The MGT and LAN Ethernet ports are compatible with
10/100/1000-Mbps connections, automatically negotiate half- and
full-duplex mode with the connecting devices, and support RJ-45
connectors. They are autosensing and automatically adjust to
straight-through and cross-over Ethernet cables. The two ports allow
you to separate traffic between the HiveManager and its
administrators from traffic between the HiveManager and the HiveAPs
it manages. The wiring terminates the same way as that on the
standard capacity HiveManager (see
"Ethernet and Console Ports" on
).
Reset Button
The reset button allows you to reboot the High Capacity HiveManager.
Insert a paper clip, or something similar, into the hole and press the
reset button between 1 and 5 seconds. After releasing the button, the
Power LED goes dark, and then glows steady amber while the
software loads and the system performs a self-test. After the
software finishes loading, the Power LED glows steady green
Power LED
The power LED conveys the operational states for the system power:
dark = no power; steady green = powered on.
On/Off Switch
The on and off switch controls the power to the HiveManager.
Serial Number Label
The serial number label contains the serial number for the device.
System Fans
The three system fans maintain an optimum operating temperature. Be
sure that air flow through the system fan vents is not obstructed.
Dual AC Power Supplies
There are two power supplies. Each three-prong AC power inlet is a
C14 chassis plug through which you can connect the HiveManager to a
100 – 240-volt AC power source using the 10-amp/125-volt IEC power
cords that ship with the product. By cabling each power supply to a
different source, they provide redundancy in the event of a single
power failure. Each power supply has a fan that maintains its
temperature. It is important that nothing obstructs the air flow to these
fans so that the power supplies do not overheat.
Table 1 High Capacity HiveManager component descriptions (Continued)
Component
Description
Содержание Aerohive APs
Страница 1: ...Aerohive Hardware Reference Guide ...
Страница 7: ...Contents 6 Aerohive ...
Страница 17: ...Chapter 1 The AP330 and AP350 Platforms 16 Aerohive ...
Страница 47: ...Chapter 3 The AP320 Platform 46 Aerohive ...
Страница 61: ...Chapter 4 The AP170 Platform 60 Aerohive ...
Страница 91: ...Chapter 8 The High Capacity HiveManager 90 Aerohive ...