10.12 Condensate Drain System Inspection
•
Inspect the condensate drain line, c
ondensate fittings, and condensate trap for signs of
weeping or leakage.
•
If you detect signs of leakage,
immediately contact your qualified service technician to inspect
the boiler and system.
•
Ensure there is sufficient neutralizer media. It is recommended to replace this media annually.
WARNING!
Have leaks fixed at once by a qualified service technician.
10.13 Low Water Cutoff Test
If an LWCO is installed, it should be tested. Testing the low water cutoff shuts the unit off. Press
the
RESET
button on the low water cutoff to turn the unit back on.