Chapter 2 — Getting to Know the DWR-10
Page 20
September 2004
Default Toolbar
The default toolbar is displayed on start-up and has five
control buttons. When another toolbar is displayed, you
can press the
Back
button to return to the default toolbar.
Item
Description
Current
This setting button can be set to one of four
possible values as you turn the knob:
10A
,
1A
,
0.1A
, and
0.01A
. The default value is 10A.
The
Current
button is locked during measuring
(current injection), but is available at all other times.
When you change the current setting, the A and B
channel ranges are updated—they stay the same if
their actual setting is available for the new current
setting. If not, they automatically switch to the
closest, most precise range value available.
A and B
Range
buttons
These setting buttons can be set to one of six
values as you turn the knob: four ranges values,
AUTO
, and
OFF
. Available range values depend on
the nominal current setting (displayed on the
Current
button). If you set the range to
AUTO
, the
title blinks, displaying
A Range
and
A Auto
alternately, indicating that the actual setting is Auto
range. See the example below.
Scroll
Readings
Press this action button to scroll through the
readings taken since the beginning of the test. It
shows one reading at a time. The corresponding
tap and winding names are also displayed. (You
can see where you are by looking at the numeric
list position above the
Save
button.)