6.4 Communication > Routing
When used as gateway, all the information received by MPC-143 is forwarded following
the chosen configuration, not storing any of these data in its memory:
o
TCP/IP - serial (request)
Making use of this mode, two devices can be connected between a TCP/IP
port and a UART. In this case, the TCP/IP device must initiate
communication and the RS485/RS232
will answer under “request”.
Parameters to be configured are:
o
"Enabled": Mode enabling/disabling.
o
"Socket live time": Duration in which socket is kept active. When the
device initiating communication sends a request command to the
slave device, communication will be shut down when this time is
reached.
o
Routing 1,2:
“TCP port”: Routing is done through this port.
“COM client”: Previously configured under “Communication
> Virtual interfaces
” tab
NOTE: After configuration is completed, click on "
Set
" button in order to
save changes.
Figure 14.
“Communication > Routing” tab. TCP/IP - serial (request)
routing configuration