background image

 

 

1.3 

Page 15

 

 

   

MPC-

143. User’s Manual 

 

 

o

 

"Modbus  RTU  Client".  This  mode  working  mode  must  be  used  when  the 
MPC-143  behaves as master in a Modbus RTU network (it sends Modbus 
requests  to  the  slaves  connected  to  the  Modbus  RTU  network).  These 
requests will be defined under the "Modbus devices" tab. Parameters to be 
configured are:

 

o

 

"Enable": Do not enable any Modbus RTU client if not needed. 

o

 

"UART":  Select  the  UART  to  be  associated  to  the  Modbus  RTU 
client. 
NOTE: Once a given UART is selected to be a Modbus RTU client, 
it cannot be used with any other configuration such as COM client. 

o

 

"Stack depth": number of requests that can be stacked in the UART 
buffer. It is recommended to set this value to 1 by default. 

o

 

“Timeout”: it defines the amount of milliseconds defined as time out. 

o

 

"Number  of  repeats":  number  of  retries  defined  in  case  of 
transmission error. 

o

 

"Delay before next request": In case peripheral devices need some 
“extra time” to answer after a received request  

NOTE: After configuration is completed, click on "

Set

" button in order to 

save changes. 
 

o

 

"Modbus RTU Server". This mode is used when the  MPC-143 will be used 
as  Modbus  slave  in  a  network.  Requests  from  a  Modbus  server  will  be 
received and answered. 

o

 

"Enable": Do not enable any Modbus RTU server if not needed. 

o

 

"UART":  Select  the  UART  to  be  associated  to  the  Modbus  RTU 
server. 
NOTE:  Once  a  given  UART  is  selected  to  be  a  Modbus  RTU 
server, it cannot be used with any other configuration such as COM 
client. 

o

 

"Address":  Define  Modbus  address  for  MPC-143.  Modbus  master 
must send requests to the given address. 

NOTE: After configuration is completed, click on "

Set

" button in order to 

save changes. 

 

 

Содержание MPC-143

Страница 1: ...MPC 143 User s Manual 1 3 11 11 2016...

Страница 2: ...0 Sara Prior User s Manual including new features such as Analog inputs and FTP client configuration 01 04 2016 1 1 Sara Prior Analog inputs configuration example added 25 05 2016 1 2 Sara Prior Alert...

Страница 3: ...3 Status indicators 6 3 4 Energy Saving mode 7 4 ANALOG INPUTS TAB 7 5 DISCRETE INPUTS TAB 10 6 COMMUNICATION TAB 11 6 1 Communication GPRS 11 6 2 Communication UARTs 13 6 3 Communication Virtual inte...

Страница 4: ...PLANATIONS 26 12 SAFETY INSTRUCTIONS 27 13 MANUFACTURER S WARRANTY 27 14 TECHNICAL DATA 28 14 1 Communication interfaces 28 14 2 Protection 29 14 3 Indication 29 14 4 Power supply 29 14 5 Construction...

Страница 5: ...RS APN user and password inside the controller NOTE Not all the models support above interfaces Check your ordering code first 2 1 USB RS232 connection Steps to be followed Connect an USB cable class...

Страница 6: ...ll the configuration parameters making use of MPC 143 Configuration Tool 2 Then under Start tab click on Save configuration button A dialog will be shown requesting user to select folder destination 3...

Страница 7: ...RTU devices reading and csv file sending over FTP Once Ext power control period has been reached the device returns to sleep and it will wake up again after Data Transmission Period has been reached...

Страница 8: ...e channel range according to the connected sensor output type In our case the temperature sensor is 0 10 VDC sensor 2 Select the low conversion point If you want to acquire the sensor value in voltage...

Страница 9: ...Current values Apart from checking the correct Analog inputs performance by using the Test tab of the MPC 143 Config tool it is possible to read directly the corresponding Modbus registers by using a...

Страница 10: ...ty and user defined multiplier Impulse multiplier o Debounce time only pulses received within one or more Debounce time intervals are registered o Mode o Discrete Input input works as a standard discr...

Страница 11: ...ommunication Within this tab different services can be configured or checked 1 GPRS connection paramete1 rs o APN access point name provided by Internet Service Provider ISP If needed by ISP credentia...

Страница 12: ...r the DDNS setting Steps to be followed are o Select Enable o Fill in information according to your DynDNS account o Click on Load from file and select dyndns org_Register_String txt which contains th...

Страница 13: ...eceived it is considered that the packet has been properly sent o Length Once the packet byte count has been reached it is considered that the packet has been properly sent o Packet time Transmission...

Страница 14: ...on parameters are o Enable Do not enable any COM client if not needed o UART Select the UART number in which a COM Client will be configured NOTE Once a given UART is selected to be a COM client it ca...

Страница 15: ...es the amount of milliseconds defined as time out o Number of repeats number of retries defined in case of transmission error o Delay before next request In case peripheral devices need some extra tim...

Страница 16: ...RS232 will answer under request Parameters to be configured are o Enabled Mode enabling disabling o Socket live time Duration in which socket is kept active When the device initiating communication se...

Страница 17: ...e Modbus client must be configured For this purpose it must be configured as much lines as Modbus requests required The number of requests can be configured in Amount of requests where Address Slave d...

Страница 18: ...tion through the Modbus RTU client With this screen it is possible to check the correct performance of Modbus devices Figure 20 Modbus devices tab Current values 6 6 Communication Data transfer Data c...

Страница 19: ...reestablished o Parameter It is filled in automatically o Register Coil Initial Modbus register address o Amount of registers Number of registers to be stored from the initial Modbus registers address...

Страница 20: ...be changed Transfer period It defines interval between CSV file sending tasks Number of last records to be read It defines maximum number of previous data stored and not sent due to communication err...

Страница 21: ...ected to the MPC 143 Figure 19 Archives tab Storage frequency configuration In case user needs to customize storage blocks signals acquisition must be configured accordingly Memory block used will be...

Страница 22: ...he internal memory go to Archives Values User archive tab This is only a test feature in order to ensure datalogging is performing correctly Figure 21 Archives tab User archive current values NOTE Int...

Страница 23: ...limit s values use file limits csv that is in program s folder 4 Enter data type corresponding to data type of used register 5 Choose limits 6 Delay time in seconds if you want to filter accidental ar...

Страница 24: ...2 SMS Alerts on Limit verification SMS alerts for limits is used for sending SMS alerts when alert conditions is set in Limit verification tab Codes of events are used in this screen to configure ale...

Страница 25: ...onizes internal RTC with PC time Figure 25 Time Parameters tab Set PC time Clock synchronization It must be enabled if synchronization between MPC 143 and any Network Time Protocol NTP server is reque...

Страница 26: ...d control signals connecting between a DTE Data Terminal Equipment and a DCE Data Circuit terminating Equipment It is commonly used in computer serial ports The standard defines the electrical charact...

Страница 27: ...is in normal range 9 Other types of devices counters etc are connected correctly by using manufacturer s regulations 10 The end of stranded conductor shall not be consolidated by soft soldering and mu...

Страница 28: ...d will replace your defective product ADVANTICSYS warranty covers the repairs manpower and materials of each manufacturing defect that may obstruct the right operation of the Product The replacement o...

Страница 29: ...ation type LED s Indicated parameters Each discrete input status Heartbeat Serial interfaces Transfer Receive GSM GPRS modem status Transfer and Receive 14 4 Power supply Power supply 15 36 VDC Power...

Страница 30: ...rements EN 61010 1 2002 Electromagnetic compatibility EN 55022 2000 A1 AC 2002 A2 2003 EN 55024 2000 A1 2003 A2 2003 EN 61000 4 2 A1 A2 2002 EN 61000 4 3 A1 2004 EN 61000 4 4 2005 EN 61000 4 5 2002 A1...

Страница 31: ...1 3 Page 31 MPC 143 User s Manual Advantic Sistemas y Servicios S L Avda Europa 14 www advanticsys com 28108 Alcobendas Madrid info advanticsys com 34 91 189 05 21...

Отзывы: