MPC-
143. User’s Manual
6.2 Communication > UARTs
The MPC-143 can have up to 5 serial ports. These UARTs can be configured by using the
MPC-143 Config. tool under the UARTs tab:
o
"Bode": Transmission rate (bauds per second).
o
"Parity": Communication Parity.
o
"Data bits": Number of data bits within the communication packet.
o
"Stop bits": Number of stop bits within the communication packet.
o
"Packetization":
o
"time": One packet time has been reached, it is considered that the
packet has been properly sent.
o
"Symbol". Every time a "packet symbol" is received, it is considered
that the packet has been properly sent.
o
“Length”. Once the "packet byte count" has been reached, it is
considered that the packet has been properly sent.
o
“Packet time”: Transmission duration.
o
“Packet symbol”: Symbol which defines packet ending.
o
“Packet byte count”: Length which defines packet size
o
“Mode”: Full duplex or half duplex
o
“Destination of DTR”: bit which defines the "Data ready" state has been
reached. It must be configured following peripheral devices connected to
MPC-143 UARTs vendor information. By default, if this information is not
available, it is recommended to select "OFF when send" option.
NOTE: After configuration is completed, click on "
Set
" button in order to save changes.
Figure 12.
“UARTs” Configuration Menu