16.
Clean pump casing, cavities, impeller and
O-ring before reassembly.
17.
Mate the motor and motor adapter to the
pump casing. Reinstall the pump casing
bolts.
18.
Reconnect the motor power cord and leads.
19.
Restore all cover panels as were removed.
E.
When the pump seal replacement procedure is
complete, the operator may restart the unit according
the section 3.
Stationary member