Table F‑2. Converter box and analog box UPP commands (Continued)
Parameter
Command
Description
Valid values are 0 to 3.
0 = Keys are not locked
1 = Enable keys lock; you can disable keys
lock by setting the value to 0 or 2, or by
cycling power
2 = Disable keys lock
3 = Enable keys lock; you can disable keys
lock by setting the value to 2, but not by
cycling power
The converter box will respond with the current
keys lock status.
Switch contact
mode
<AA>t1<VAL>
For analog box with
multiple connections,
specify the analog out:
<AA>t1sX<VAL>
“1” is numeric.
Sets the mode for switch contact
SP1
of the
converter box.
Valid values are 0 to 2.
0 = Off
1 = Contact is switched (from open
to closed relay) when the temperature
is higher than the defined threshold
temperature
2 = Contact is switched (from open to
closed relay) when the temperature is lower
than the defined threshold temperature
Source for the
switch contact
<AA>ss<VAL>
For analog box with
multiple connections,
specify the analog out:
<AA>sssX<VAL>
Sets the temperature source for the switch
contact on the converter box.
Valid values are 0 and 1.
0 = Temperature measured with the sensor
head
1 = Internal temperature of the sensor head
Sensor head for
the switch
contact
<AA>sx<VAL>
For analog box with
multiple connections,
specify the analog out:
<AA>sxsX<VAL>
Sets the sensor head to be used for the switch
contact on the converter box. The set value
corresponds to either the assigned sensor head
address or the given sensor head number.
Valid values are A1 to A8 or N1 to N8.