FORM NO. 56043111 - Adhancer
™
-
19
SOLUTION SYSTEM
SOLUTION FILTER AND BALL VALVE REMOVAL
1 Drain the solution tank using the solution drain hose.
2
See Figure 4.
Loosen the (2) Hose Clamps
(R)
and pry off the inlet Solution Hose
(S)
and outlet Solution Hose
(T)
from the
Ball Valve
.
3 Remove the (2) Hose Clamps
(U)
that secure the Filter/Valve Assembly to the chassis and remove the Assembly from the machine.
SOLUTION PUMP REMOVAL
Drain the solution tank or turn the solution
fi
lter ball valve to the off position to prevent solution loss.
1
See Figure 4.
2
Loosen the (2) Hose Clamps
(V)
and pry off inlet Solution Hose
(T)
and outlet Solution Hose
(W)
from Solution Pump
(X).
Remove the (2) Screws
3
(Y)
that secure the Solution Pump
(X)
to the Chassis.
Disconnect the Solution Pump Electrical Connector
4
(Z)
. (Note that you may need to cut a cable tie.)
Remove the Solution Pump
5
(X)
from the machine.
Note:
Refer to the
APPENDIX
at the back of this manual for solution system
fl
ow schematics and detergent system information.
FIGURE 4
Содержание Adhancer 56316001(W32-C)
Страница 1: ...7 08 FORM NO 56043111 SERVICE MANUAL Models 56316000 W28 C 56316001 W32 C Adhancer...
Страница 2: ......
Страница 7: ...FORM NO 56043111 Adhancer 5 TECHNICAL SPECIFICATIONS...
Страница 25: ...FORM NO 56043111 Adhancer 23 SCRUB SYSTEM FIGURE 2...
Страница 51: ...FORM NO 56043111 Adhancer 49 FIGURE 4...
Страница 53: ...FORM NO 56043111 Adhancer 51 FIGURE 5 ELECTRICAL SYSTEM...
Страница 59: ...FORM NO 56043111 Adhancer 57 FIGURE 6 ELECTRICAL SYSTEM...
Страница 68: ......
Страница 74: ......