Section 5 User Interface Guide
TRACER 6000 Series Split System Manual
82
612806320L1-1B
> M
ANAGEMENT
/SNMP P
ORT
C
ONFIGURATION
> SNMP G
ET
C
OMMUNITY
Defines the community name for Get access (to poll the TRACER for status information). This value must
match the Get name defined on the network management stations (NMS). Get access is read only access.
The default name is
public
.
> M
ANAGEMENT
/SNMP P
ORT
C
ONFIGURATION
> SNMP P
UT
C
OMMUNITY
Defines the community name for Set access (to change TRACER configuration parameters through
SNMP). This value must match the Get or Set name defined on the NMS. The default name is
private
.
> M
ANAGEMENT
/SNMP P
ORT
C
ONFIGURATION
> SNMP T
RAP
C
OMMUNITY
Defines the community name for trap destinations. This name must match the community name defined on
the NMS. The default name is
SNMP_trap
.
> M
ANAGEMENT
/SNMP P
ORT
C
ONFIGURATION
> SNMP T
RAP
H
OST
#0 - #4
Identifies the IP address in dotted decimal notation of the NMS for the TRACER to send SNMP traps to.
Up to five trap destinations can be entered.
> P
ING
U
TILITY
Figure 31 shows the Ping Utility menu page, which contains the parameters for performing a ping test out
of the 10/100BaseT/TX
MGMT
Ethernet interface.
Figure 31. Ping Utility
> P
ING
U
TILITY
> P
ING
A
DDRESS
Specifies the IP address to ping (in dotted decimal notation).
Содержание TRACER 6000 SERIES
Страница 10: ...Table of Contents TRACER 6000 Series Split System Manual 10 Copyright 2005 ADTRAN Inc 612806320L1 1B...
Страница 14: ...Section 1 System Description TRACER 6000 Series Split System Manual 14 Copyright 2005 ADTRAN Inc 612806320L1 1B...
Страница 88: ...Section 5 User Interface Guide TRACER 6000 Series Split System Manual 88 612806320L1 1B...
Страница 90: ...Section 6 Detail Level Procedures TRACER 6000 Series Split System Manual 90 612806320L1 1B...
Страница 98: ...Section 5 DLP 3 TRACER 6000 Series Split System Manual 98 Copyright 2005 ADTRAN Inc 612806320L1 1B...