Section 3 Engineering Guidelines
TRACER 6000 Series Split System Manual
42
Copyright © 2005 ADTRAN, Inc.
612806320L1-1B
VT100 Terminal Interface
Data Rate
9600, 19200, 38400, 57600, 115200 bps
Data Bits
8
Parity
None
Stop Bits
1
Terminal Emulation
VT100
Mechanical and Environmental (IDU)
Operating Temperature
-25°C to 65°C
Size
1.7 inch (4.4 cm) H
17.2 inch (43.7 cm) W
11.4 inch (28.9 cm) D
Humidity
95 percent, noncondensing
Weight
5 lbs (2.3 kg)
Mechanical and Environmental (ODU)
Operating Temperature
-40°C to 65°C
Size
12.74 inch (32.36 cm) H
10.24 inch (26.01 cm) W
4.78 inch (12.14 cm) D
Humidity
95 percent, noncondensing
Weight
9.5 lbs (4.3 kg)
Power
Input Voltage
21 to 60 VDC, either polarity referenced to ground
Power Consumption
< 25 W
Connector
2-pin terminal block (DC)
Fuse
2 A, 250 V slow-blo fuse (2-inch)
Network Modules
Quad E1 Module
(120
Ω
Interface)
Connection
Four RJ-45 interfaces
Capacity
4xE1 (CCITT G.703)
Line Code
HDB3 (default), AMI
Alarms
LOS, LCV, AIS, RMT, OOF, CRC
Loopbacks
Local and remote line and link
Table 16. At-A-Glance Specifications (Continued)
Hardware
Description
Specification
Содержание TRACER 6000 SERIES
Страница 10: ...Table of Contents TRACER 6000 Series Split System Manual 10 Copyright 2005 ADTRAN Inc 612806320L1 1B...
Страница 14: ...Section 1 System Description TRACER 6000 Series Split System Manual 14 Copyright 2005 ADTRAN Inc 612806320L1 1B...
Страница 88: ...Section 5 User Interface Guide TRACER 6000 Series Split System Manual 88 612806320L1 1B...
Страница 90: ...Section 6 Detail Level Procedures TRACER 6000 Series Split System Manual 90 612806320L1 1B...
Страница 98: ...Section 5 DLP 3 TRACER 6000 Series Split System Manual 98 Copyright 2005 ADTRAN Inc 612806320L1 1B...