Your TRACER 6320 ODU shipment includes the following items:

TRACER 6320 ODU

ODU mounting hardware 

Your Quad T1 module shipment includes the following items:

Quad T1 module

Quad T1 module quick start guide

Your Quad E1 module (120

 interface) shipment includes the following items:

Quad E1 module

Quad E1 module quick start guide

Your Quad E1 module (75

 interface) shipment includes the following items:

Quad E1 module

Quad E1 module quick start guide

DB-25 to DB-25 cable for connecting to the 75

 BNC breakout panel

Your Octal 75

 E1 Breakout Panel shipment includes the following items:

Octal  75

 E1 Breakout Panel

23-inch rack mounting brackets (ADTN P/N 3265622@A)

Octal  75

 E1 Breakout Panel quick start guide

Your Quad Ethernet Switch module shipment includes the following items:

Quad Ethernet Switch module

Quad Ethernet Switch module quick start guide

Customer Provides

Base System

The following items are necessary to install the TRACER 6000 Series split system and are not provided:

21 to 60 VDC power source with either polarity referenced to ground

DB-9 cable for VT100 access

Ethernet cable (for Telnet, SNMP, or TFTP access)

IF coaxial cable with N-type connectors for feedline between IDU and ODU

Quad T1 Module

T1 cables for connecting the Quad T1 module to external T1 devices

Содержание TRACER 6000 SERIES

Страница 1: ...1B June 2005 TRACER 6000 SERIES Split System Manual 12806200L1 TRACER 6200 Modular Indoor Unit IDU 12806320L1A TRACER 6320 5 8 GHz Outdoor Unit ODU Plan A 12806320L1B TRACER 6320 5 8 GHz Outdoor Unit...

Страница 2: ...mages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication About this Manual This manual provides a complete description of the TRACER 6000 Series...

Страница 3: ...f Changes A March 2005 Initial release of manual B June 2005 Added new real time power reportings and support for new Quad E1 120 module Notes provide additional useful information Cautions signify in...

Страница 4: ...tub wash bowl kitchen sink laundry tub in a wet basement or near a swimming pool 2 Avoid using a telephone other than a cordless type during an electrical storm There is a remote risk of shock from li...

Страница 5: ...uses and can radiate radio frequency energy If not installed and used in accordance with the instructions it may cause interference to radio communications The limits are designed to provide reasonab...

Страница 6: ...f the antenna at a distance less than 15 feet 4 6 meters Installation on towers masts or rooftops not accessible to the general population is recommended or Mount the antenna in a manner that prevents...

Страница 7: ...to obtain information regarding equipment currently in house or possible fees associated with repair Identify the RMA number clearly on the package below address and return to the following address Pr...

Страница 8: ...program offers multiple types and levels of maintenance services which allow you to choose the kind of assistance you need This support is available at For questions call the ACES Help Desk Training T...

Страница 9: ...rovides detailed descriptions of all menu options and configuration parameters available for the TRACER 6000 Series split system Section 6 Detail Level Procedures 89 Provides detailed instructions on...

Страница 10: ...Table of Contents TRACER 6000 Series Split System Manual 10 Copyright 2005 ADTRAN Inc 612806320L1 1B...

Страница 11: ...RACER 6000 Series split system CONTENTS System Overview 12 Features and Benefits 12 Configuration and Management 12 Operational 13 Available Interface Modules 13 E1 Network Module with 120 Interface 1...

Страница 12: ...s provided for radio functionality Triple DES 3DES security provides additional protection from unauthorized access without requiring any additional external security appliances Future upgrades and en...

Страница 13: ...rm reporting capability Testing support through local and remote line and link loopbacks E1 Network Module with 75 Interface Four E1 circuits provided through a single DB 25 75 connector Complies with...

Страница 14: ...Section 1 System Description TRACER 6000 Series Split System Manual 14 Copyright 2005 ADTRAN Inc 612806320L1 1B...

Страница 15: ...RACER RSSI Test Points 23 Antenna Beam Patterns 23 Fresnel Zones Earth Curvature and Antenna Heights 23 Other Considerations 26 Path Availability 26 FIGURES Figure 1 Example Microwave Path with Parame...

Страница 16: ...ed signal power is often expressed in decibel format In general any quantity can be expressed in decibels If the quantity x is a power level in Watts the decibel equivalent is defined as If the quanti...

Страница 17: ...omponents 4 RECEIVER POWER The viability of a particular microwave path is determined by the power of the transmitted microwave signal the transmit and receive antenna gain distance and accumulated sy...

Страница 18: ...eristics of the antennas installed for each link In other words the size of the dish determines the antenna gain Using a parabolic dish antenna results in the best performance Antenna gains are specif...

Страница 19: ...antennas For the TRACER 6320 these distances can range up to 30 miles 48 27 meters System Losses L System losses are defined by RF coaxial cable loss connector losses and losses added from any additi...

Страница 20: ...s where f carrier frequency Hz carrier wavelength c f meters d path distance meters c speed of light free space meters In areas where lightning strikes are frequent a lightning arrestor should be inst...

Страница 21: ...quency microwave communication experiences more path loss than lower frequency microwave communication The path loss values for various path lengths for the TRACER 5 8 GHz system are listed in Table 4...

Страница 22: ...t required the delivered bandwidth can be decreased to four or two channels and the receiver sensitivity will be improved as follows 6 ANTENNA INFORMATION The overall wireless system is directly affec...

Страница 23: ...nd RSSI voltage This sheet is useful for verifying link budget calculations and ensuring proper equipment installation Antenna Beam Patterns Directly related to the subject of antenna alignment is the...

Страница 24: ...The curvature of the Earth becomes a legitimate obstruction for path lengths of 7 miles 11 26 kilometers or greater and must also be accounted for when determining minimum antenna heights The aggrega...

Страница 25: ...gineering Basics 612806320L1 1B Copyright 2005 ADTRAN Inc 25 Table 8 Minimum Antenna Height for Given Path Lengths Metric Path Length kilometers Min Antenna Height meters 2 5 4 8 6 10 8 11 10 13 14 16...

Страница 26: ...rier frequency GHz d path length kilometers F fade margin dB Terrain Factor a The terrain factor is a quantity that compensates the link availability for different types of terrain Generally speaking...

Страница 27: ...ral microwave links operating in areas with high humidity will have less availability than those in arid areas primarily because water is a dispersive mechanism to microwave energy and causes the main...

Страница 28: ...Section 2 Microwave Path Engineering Basics TRACER 6000 Series Split System Manual 28 Copyright 2005 ADTRAN Inc 612806320L1 1B...

Страница 29: ...larm Contacts Plug In Terminal Block 35 To ODU Interface N Type Connector 36 TRACER 6320 Outdoor Unit ODU 36 RSSI Monitoring Interface 37 To IDU 37 Network Module Interfaces 37 4xE1 Module with 120 In...

Страница 30: ...ntact Connector Pinout 35 Table 10 ODU Bottom Panel Description 36 Table 11 4xE1 Module with 120 Interface RJ 45 Connector Pinout 37 Table 12 4xE1 Module DB 25 Connector Pinout 38 Table 13 DB 25 to 75...

Страница 31: ...anagement and configuration an AUX RS232 interface RJ 45 that provides an end to end serial port interface at 9600 bps and status LEDs to provide visual information about the TRACER system Figure 1 id...

Страница 32: ...nt to point connection between the local and remote systems over the RF link Table 3 on page 33 shows the pinout Table 2 TRACER 6200 LEDs For these LEDs This color light Indicates that PWR Green solid...

Страница 33: ...al ground 2 RTS Attached Equipment Request to send unused 3 TXDATA Attached Equipment Transmit data from attached equipment 4 DSR TRACER Data set ready 5 RXDATA TRACER Received data to attached equipm...

Страница 34: ...Detailed discussions including pinouts of rear panel components where applicable follow the table Name Connector Description A Network Module Slots N A Dual network module slots for system flexibility...

Страница 35: ...oximately 0 52 A 25 W 48 V Table 8 shows the DC power connection pinout Fuse The fuse holder accessible from the rear panel of the TRACER 6200 accepts a generic 2 A 250 V 2 inch slow blo fuse Alarm Co...

Страница 36: ...the IDU The power supply is protected from a short circuit on the IDU ODU connection via a thermal protection device 5 TRACER 6320 OUTDOOR UNIT ODU Figure 3 identifies the features of the TRACER 6320...

Страница 37: ...ection also provides a full duplex control and monitoring channel between the IDU and ODU on a 4 5 MHz carrier Additionally this interface accepts DC power from the IDU taken directly from the voltage...

Страница 38: ...r the 4xE1 network module A separate breakout panel is available to provide 75 BNC unbalanced interfaces see Table 13 on page 39 for the pinout of the 75 cable Figure 4 displays the E1 breakout panel...

Страница 39: ...me ESF and Super Frame SF framing support Manual line build out Network performance monitoring and reporting Test loopbacks both line and link Table 14 on page 40 provides the RJ 45 interface pinout f...

Страница 40: ...ut for the Quad Ethernet Switch module 7 AT A GLANCE SPECIFICATIONS Table 16 on page 41 contains a list of specifications for the TRACER 6000 Series split system Table 14 4xT1 Module RJ 45 Connector P...

Страница 41: ...uency Plan Plan A Band Plan 1 Tx 5 744 GHz Rx 5 824 GHz 2 Tx 5 747 GHz Rx 5 827 GHz 3 Tx 5 751 GHz Rx 5 831 GHz Plan B Band Plan 1 Tx 5 824 GHz Rx 5 744 GHz 2 Tx 5 827 GHz Rx 5 747 GHz 3 Tx 5 831 GHz...

Страница 42: ...nical and Environmental ODU Operating Temperature 40 C to 65 C Size 12 74 inch 32 36 cm H 10 24 inch 26 01 cm W 4 78 inch 12 14 cm D Humidity 95 percent noncondensing Weight 9 5 lbs 4 3 kg Power Input...

Страница 43: ...Loopbacks Local and remote line and link Quad T1 Module Connection Four RJ 45 interfaces Capacity 4xT1 ANSI T1 403 AT T 54016 and 62411 Line Code B8ZS default AMI Alarms AIS Red Yellow BPVs LOS Quad E...

Страница 44: ...Section 3 Engineering Guidelines TRACER 6000 Series Split System Manual 44 Copyright 2005 ADTRAN Inc 612806320L1 1B...

Страница 45: ...49 Mounting Options 50 Indoor Unit IDU 50 Outdoor Unit ODU 51 Installing Modules 52 Instructions for Installing Network Modules 53 Connecting the MODULE Interfaces 53 Quad T1 Module Interfaces 53 Qua...

Страница 46: ...ansit immediately file a claim with the carrier then contact ADTRAN Customer Service see Warranty Customer Service Product Support Information and Training information in the front of this manual Cont...

Страница 47: ...to the 75 BNC breakout panel Your Octal 75 E1 Breakout Panel shipment includes the following items Octal 75 E1 Breakout Panel 23 inch rack mounting brackets ADTN P N 3265622 A Octal 75 E1 Breakout Pa...

Страница 48: ...at one end of the link will transmit in band plan 1 of frequency plan A the lower portion of the spectrum and receive in band plan 1 of frequency plan B the upper portion Consequently the receiver at...

Страница 49: ...ary equipment grounding conductor shall be in compliance with the rules for terminating bonding jumpers at Part K or Article 250 of the National Electrical Code ANSI NFPA 70 Termination of the supplem...

Страница 50: ...Figure 3 on page 51 equipment racks using the supplied rackmount brackets 3265498 B Follow these steps to mount the TRACER 6200 into a rack Figure 2 19 inch Rackmount Illustration Instructions for Rac...

Страница 51: ...outdoors using the provided mounting hardware Follow these steps to mount the TRACER 6320 ODU onto an outdoor structure see Figure 4 on page 52 for the accompanying illustration Instructions for Moun...

Страница 52: ...ation as viewed from the rear of the TRACER 6200 IDU The functionally identical option slots only accept TRACER 6000 Series modules Figure 5 TRACER 6200 Network Module Slot Designation Access modules...

Страница 53: ...can be damaged by static electrical discharge Before handling modules put on an antistatic discharge wrist strap to prevent damage to electronic components Place modules in antistatic packing materia...

Страница 54: ...e s DB 25 connector and then attach the other end of the cable labeled TO PANEL to the BNC breakout panel The 75 unbalanced interfaces provided by the breakout panel are available for connection to st...

Страница 55: ...U Error History 66 RF Link Max Min Received Power History 67 RF Link Min Max Received Signal Quality History 68 Datapath Provisioning 69 4xE1 Module Configuration Status History Main Screen 70 E1x Sta...

Страница 56: ...Status History Main Screen 74 Figure 20 T1x Status Configuration Loopback 74 Figure 21 T1 Local Link Loopback 76 Figure 22 T1 Remote Link Loopback 76 Figure 23 T1 Local Line Loopback 76 Figure 24 T1...

Страница 57: ...erial interface should be configured to NONE for proper operation Once a terminal is connected press Enter until the login screen appears The default password for the TRACER is password Terminal Menu...

Страница 58: ...initial connection Enter twice Refresh the screen Ctrl l Ctrl r Exit the menu system and return to the login screen Ctrl z Close the Telnet session or toggle the modem signalling to hang up an attache...

Страница 59: ...igure 2 TRACER System Status A Elapsed Time The top of the TRACER System Status menu page displays the elapsed time the TRACER system has been operational since the last power reset The menu structure...

Страница 60: ...oise ratio and features a colon marker to indicate 10 6 bit error rate This indicator is useful as a diagnostic tool to help 4XT1 MODULE A visual status of current errors alarms on the T1 interfaces f...

Страница 61: ...ts using a series of symbols and the actual real time value in dBm The more symbols displayed the stronger the signal If the link is down in either direction and remote end data is unavailable DATA NO...

Страница 62: ...FIGURATION SITE NAME Provides a user defined alphanumeric description up to 25 characters for the TRACER system SYSTEM CONFIGURATION SERIAL NUMBER Displays the serial number for the unit The serial nu...

Страница 63: ...system Select one of the following 5 MIN 10 MIN default 15 MIN 30 MIN 45 MIN 60 MIN or OFF SYSTEM CONFIGURATION PASSWORD Sets the password for password protection of the TRACER terminal interface Ente...

Страница 64: ...atures If the link is down in either direction and remote end data is unavailable DATA NOT AVAILABLE displays in place of the symbols This parameter is display only RF LINK CONFIGURATION TX POWER Allo...

Страница 65: ...N is set to ENABLED the system sequentially applies the three keys entered in the SUBKEY 0 1 and 2 fields to each 64 bit block of data transmitted over the RF link The remote system uses the same keys...

Страница 66: ...ys the error statistics available from the system for the RF link and the communications link between the IDU and ODU Detailed error statistics are displayed in 15 minute and 24 hour increments Figure...

Страница 67: ...received power level MIN and MAX represents the minimum and maximum values of received signal levels in 24 hour or 15 minute increments and is displayed as a numerical value in dBm Press n to view the...

Страница 68: ...uality Press n to view the next 8 hour segment of 15 minute totals and p to view the previous 8 hour segment Radio links with consistently high MIN and MAX numbers should not experience interference R...

Страница 69: ...ION Defines the active channels A B C D on each installed T1 module or the bandwidth dedicated to the Quad Ethernet Switch module in 2 Mbps steps To activate a channel press Enter and use the spacebar...

Страница 70: ...12 E1 Module Configuration Status History Main Screen E1X STATUS CONFIGURATION LOOPBACK Figure 13 shows the E1x Status Configuration Loopback menu page which displays a real time graphical representa...

Страница 71: ...the E1 signal is properly timed Configure the framing format using the SIGNALING menu to enable the TRACER to monitor incoming framing error events and indicate problems with the attached metallic ser...

Страница 72: ...LINK REMOTE Activates a loopback at the remote TRACER E1 framer towards the local end of the wireless link see Figure 15 Use the remote LINK loopback to loop the data transmitted from the local end of...

Страница 73: ...Seconds SES on the E1 interface The following events qualify as an ES LOS OOF LCV or CRC error An SES is caused by a loss of signal or an out of frame event The error count for the most recent 24 hou...

Страница 74: ...19 T1 Module Configuration Status History Main Screen T1X STATUS CONFIGURATION LOOPBACK Figure 20 shows the T1x Status Configuration Loopback menu page which displays a real time graphical representa...

Страница 75: ...SIGNALING menu to enable the TRACER to monitor incoming framing error events and indicate problems with the attached metallic service The TRACER supports both extended superframe ESF and superframe D4...

Страница 76: ...opback to loop the data transmitted from the local end of the link across the radio link to the local end of the link This loopback tests the integrity of the radio link and all the associated digital...

Страница 77: ...ES AIS LOS or LOF alarm second a single BPV excessive zero event or a single parity bit An SES is caused by an AIS LOS or LOF alarm second excessive BPVs or framed parity bit errors causing a line bi...

Страница 78: ...history parameters for the selected Ethernet Switch module Figure 26 Ethernet Switch Module Configuration Status History Main Screen ETHERNET SWITCH CONFIGURATION Figure 27 shows the Ethernet Switch...

Страница 79: ...the system can be displayed on the Ethernet Switch Status page ETHERNET SWITCH STATUS Figure 28 shows the Ethernet Switch Status menu page which displays the current speed and duplex operation for ea...

Страница 80: ...an indicator of congestion inside the TRACER switch ETHERNET SWITCH STATUS RX PACKET ERRORS Displays a counter of all received data packets that are greater than or equal to 64 bytes in length and ha...

Страница 81: ...address is in dotted decimal notation four decimal numbers each in the range of 0 to 255 separated by periods This value is set to 255 255 255 0 by default This part of the destination IP address is...

Страница 82: ...tch the Get or Set name defined on the NMS The default name is private MANAGEMENT SNMP PORT CONFIGURATION SNMP TRAP COMMUNITY Defines the community name for trap destinations This name must match the...

Страница 83: ...t START or stop ABORT a ping request reset the ping statistics RESET STATS or return the ping configuration parameters to their default values DEFAULT VALUES PING UTILITY DELAY Read Only Displays the...

Страница 84: ...WARE UPGRADE UTILITY TFTP FILENAME Available for TFTP transfers only Specifies the name of the update file to retrieve from the TFTP server Enter the full filename for the file Some TFTP servers requi...

Страница 85: ...error message displays Refer to DLP 5 Updating the Firmware Using TFTP on page 101 for more details on available error messages FIRMWARE UPGRADE UTILITY REMOTE CURRENT STATUS Available for TFTP updat...

Страница 86: ...o operate in a daisy chain fashions providing the user with configuration management and monitoring function for all TRACER systems in the chain as well as any other Ethernet capable device located on...

Страница 87: ...the bridge table A shorter time produces a more dynamic bridge table allowing addresses to change network segments without causing extra forwarded traffic A longer time reduces the amount of unnecess...

Страница 88: ...Section 5 User Interface Guide TRACER 6000 Series Split System Manual 88 612806320L1 1B...

Страница 89: ...e system and upgrading firmware CONTENTS DLP 1 Connecting a VT100 Terminal or PC to the CRAFT Port 91 DLP 2 Logging into the TRACER System 93 DLP 3 Setting IP Parameters for the TRACER System 95 DLP 4...

Страница 90: ...Section 6 Detail Level Procedures TRACER 6000 Series Split System Manual 90 612806320L1 1B...

Страница 91: ...R Prerequisite Procedures The TRACER must be powered up for terminal communication to function Tools and Materials Required A VT100 compatible terminal or PC with terminal emulation software An approp...

Страница 92: ...rm one of the following steps Set the parameters of the VT100 terminal or PC to 9600 baud rate 8 data bits No parity 1 stop bit No flow control If the terminal has a parallel setting disable this sett...

Страница 93: ...C to the CRAFT Port on page 91 To prevent electrical shock do not install equipment in a wet location or during a lightning storm Electronic equipment can be damaged by static electrical discharge Bef...

Страница 94: ...cursor at the LOGIN field indicates that a password must be entered 2 Enter the password for the TRACER at the LOGIN field The manufacturer s default password for the TRACER system is password in lowe...

Страница 95: ...s connected to an IP network and is powered up Please see your Network Administrator for the proper assignment of the following parameters IP ADDRESS SUBNET MASK and DEFAULT GATEWAY To prevent electri...

Страница 96: ...ximum rights details are in DLP 2 Logging into the TRACER System on page 93 2 Press m to activate the Main menu page From the Main menu page press 7 to select MANAGEMENT UTILITIES 3 From the MANAGEMEN...

Страница 97: ...nu page select the IP ADDRESS field and press Enter Type the IP address provided by your network manager and press Enter to accept the change Repeat the process for the SUBNET MASK and DEFAULT GATEWAY...

Страница 98: ...Section 5 DLP 3 TRACER 6000 Series Split System Manual 98 Copyright 2005 ADTRAN Inc 612806320L1 1B...

Страница 99: ...provisioning tasks detailed in DLP 3 Setting IP Parameters for the TRACER System on page 95 should be complete Tools and Materials Required Access to a PC or other computer connected to the LAN To pr...

Страница 100: ...45 connector Verify the IP address subnet mask and default gateway on the remote computer system If these steps fail contact the LAN Administrator for assistance 3 Telnet to the TRACER From the same c...

Страница 101: ...ort and a TFTP server See DLP 6 Updating the Firmware Using XMODEM on page 105 for instructions on using XMODEM Tools and Materials Required A PC with Telnet client software A TFTP server accessible o...

Страница 102: ...TFTP provides the capability to upgrade both sections of the local and remote units Valid choices are LOCAL IDU LOCAL ODU REMOTE IDU and REMOTE ODU 9 View CURRENT UPDATE STATUS to verify the progress...

Страница 103: ...Service channel communications over the RF link allow a user connected to a local system to upgrade the firmware of a remote system Before the remote system begins the firmware upgrade process a compl...

Страница 104: ...th the ODU to obtain the current firmware revision of the system This only occurs when the local or remote ODU is selected from the UPGRADE DESTINATION field REQUIRED COMMUNICATIONS LINK IS DOWN Indic...

Страница 105: ...ugh your Telnet client refer to your Telnet client documentation for more details on file transfer specifics See DLP 5 Updating the Firmware Using TFTP on page 101 for instructions on using TFTP Tools...

Страница 106: ...for possible configuration errors 10 From the terminal emulation software begin the XMODEM upload by using the appropriate command sequence This may take several minutes If necessary refer to the term...

Страница 107: ...CER 6000 split system 108 MIB Compilation Order 108 Traps Supported by the TRACER 6000 split system 109 MIB Variables Supported by the TRACER 6000 split system 111 TABLES Table 1 MIBs Supported by the...

Страница 108: ...types rfc2863 mib IF MIB updated MIB II rfc3418 mib SNMPv2 MIB rfc3595 mib PerfHist TC MIB needed for RFC2495 rfc3635 mib EtherLike MIB adtran mib ADTRAN product MIB needed to locate the ADTRAN specif...

Страница 109: ...change in the Code Violation CV state has occurred and the CV alarm is active adTRACERCRC a change in the Cyclic Redundancy Check CRC state has occurred and the CRC alarm is active adTRACERmfLOF a cha...

Страница 110: ...Remote Alarm RA has occurred and the Multiframe RA alarm is inactive adTRACERlineLoopbackOff a change in the line loopback state has occurred and the line loopback is inactive adTRACERlinkLoopbackOff...

Страница 111: ...adProdName DisplayString RO adProdPartNumber DisplayString RO adProdCLEIcode DisplayString RO adProdSerialNumber DisplayString RO adProdRevision DisplayString RO adProdSwVersion DisplayString RO adPro...

Страница 112: ...rm Integer RW adDS1TotalArm Integer RW adDS1FarCurrentArm Integer RW adDS1FarTotalArm Integer RW adDS1CurrentThreshold adDS1CurrentThrsES Integer RW adDS1CurrentThrsSES Integer RW adDS1CurrentThrsSEFS...

Страница 113: ...CERactiveChannels Integer RW adTRACERchannelSelect adTRACERdsx1ChannelSelectTable adTRACERdsx1ChannelSelectEntry AdTRACERdsx1ChannelSelectEntry adTRACERdsx1ChannelSelectIdx Integer RO adTRACERdsx1Chan...

Страница 114: ...CERswitchWanStatusEntry AdTRACERswitchWanStatusEntry adTRACERswitchWanStatusIdx Integer RO adTRACERswitchWanTxPackets Integer RO adTRACERswitchWanTxPacketsDrop Integer RO adTRACERswitchWanRxPackets In...

Страница 115: ...s Integer RO adTRACERIntervalMaxRxLs Integer RO adTRACERIntervalMinRxLs Integer RO adTRACERIntervalMaxRxQs Integer RO adTRACERIntervalMinRxQs Integer RO adTRACERIntervalValidData TruthValue RO adTRACE...

Страница 116: ...chChannelSelectTable AdTRACERremoteSwitchChannelSelectEntry adTRACERremoteSwitchChannelSelectEntry adTRACERremoteSwitchChannelSelectIdx Integer RO adTRACERremoteSwitchChannelSelection Integer RW adTRA...

Страница 117: ...etsDrop Integer RO adTRACERremoteswitchWanRxPacketError Integer RO adTRACER6420remoteTrapIP adTRACERremoteTrapIpHost1 IpAddress RW adTRACERremoteTrapIpHost2 IpAddress RW adTRACERremoteTrapIpHost3 IpAd...

Страница 118: ...eIntervalMaxRxQs Integer RO adTRACERremoteIntervalMinRxQs Integer RO adTRACERremoteIntervalValidData TruthValue RO adTRACERremoteTotalTable AdTRACERremoteTotalEntry adTRACERremoteTotalEntry adTRACERre...

Страница 119: ...NTENTS Overview 120 LED Indicators 120 PWR LED 120 TST LED 120 RF DWN LED 120 RF LOW LED 121 T1 Interface Alarms 121 E1 Interface Alarms 122 LAN LEDs 123 RF Errors 123 Step by Step Troubleshooting 124...

Страница 120: ...ort on the IDU 5 Verify the integrity of the coaxial feedline cable between the IDU and ODU 6 Verify the integrity of the lightning arrestors both RF and IF TST LED The TST LED will flash once amber d...

Страница 121: ...herproof the replacements 3 Verify the RF signal path by verifying the antenna alignment 4 Check the integrity of lightning arrestors T1 Interface Alarms All active T1 alarms are displayed in the T1X...

Страница 122: ...Actions 1 Display the E1 X STATUS screen and check the E1 X INTERFACE ALARM field to identify the active alarm 2 Follow the steps below for the appropriate alarm LOS Alarm Loss of Signal LOS ALARM is...

Страница 123: ...nd in band RF interference These types of errors are remedied by performing a detailed line of site microwave path study to determine whether a microwave link is feasible for the terrain and environme...

Страница 124: ...mately 100 mW 20 dBm of RF power The actual power level measured by the meter analyzer will be less than 100 mW due to RF losses through the coaxial cable and is a function of the cable type and lengt...

Страница 125: ...equipment This will verify the data path across the RF link Installing Configuring T1 Hardware 1 If possible attach any or all of the intended T1 hardware to the TRACER units using the same workbench...

Страница 126: ...ion resolve any remaining E1 equipment to TRACER configuration issues before field installation See E1 Interface Alarms on page 122 for more information on resolving E1 interface alarm conditions Inst...

Отзывы: