Section 3 Engineering Guidelines
TRACER 6000 Series Split System Manual
38
Copyright © 2005 ADTRAN, Inc.
612806320L1-1B
4xE1 Module with 75
Ω
Interface
The 4xE1 network module provides four E1 interfaces (through a single DB-25 interface) that provide the
following functions:
•
AMI or HDB3 coding
•
Framed, multi-framed, and unframed framing support
•
Network performance monitoring and reporting
•
Test loopbacks (both line and link)
Table 12 provides the DB-25 interface pinout for the 4xE1 network module. A separate breakout panel is
available to provide 75
Ω
BNC unbalanced interfaces (see Table 13 on page 39 for the pinout of the 75
Ω
cable). Figure 4 displays the E1 breakout panel.
Table 12. 4xE1 Module DB-25 Connector Pinout
Pin
Name
Description
1
E1D RX
Receive signal for E1 D interface
2
E1D TX
Output signal for E1 D interface
3
GND
Ground
4
E1C RX
Receive signal for E1 C interface
5
E1C TX
Output signal for E1 C interface
6
GND
Ground
7
E1B RX
Receive signal for E1 B interface
8
E1B TX
Output signal for E1 B interface
9
GND
Ground
10
E1A RX
Receive signal for E1 A interface
11
E1A TX
Output signal for E1 A interface
12-25
GND
Ground
Содержание TRACER 6000 SERIES
Страница 10: ...Table of Contents TRACER 6000 Series Split System Manual 10 Copyright 2005 ADTRAN Inc 612806320L1 1B...
Страница 14: ...Section 1 System Description TRACER 6000 Series Split System Manual 14 Copyright 2005 ADTRAN Inc 612806320L1 1B...
Страница 88: ...Section 5 User Interface Guide TRACER 6000 Series Split System Manual 88 612806320L1 1B...
Страница 90: ...Section 6 Detail Level Procedures TRACER 6000 Series Split System Manual 90 612806320L1 1B...
Страница 98: ...Section 5 DLP 3 TRACER 6000 Series Split System Manual 98 Copyright 2005 ADTRAN Inc 612806320L1 1B...