A1-User’s Manual
90
10.05 DI contact type selection
Range: 0x00 ~ 0xFF
Initial value: 0x00
It is possible to change the status of DI input type as N.O or N.C
Example Data: 0000000011110000
Meaning: DI8~DI5 Normal close type, DI4~DI1 Normal open type
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
It displays when extension I/O card is connected DI8 DI7 DI6 DI5 DI4 DI3 DI2 DI1
10.06 DI1 ON delay time
Range: 0.0 ~ 3000 Sec in 0.1 Sec
Initial value: 0.0
Sec
Defines the activation delay for digital input DI1
0
Ton
DI status
1
0
1
Delayed
DI status
Toff
Ton
Toff
Time
Ton:
'10.06' (DI1 On delay time)
Toff:
'10.07' (DI1 Off delay time)
10.07 DI1 OFF delay time
Range: 0.0 ~ 3000 Sec in 0.1 Sec
Initial value: 0,0
Sec
Defines the activation ON delay for digital input DI1
10.08 DI2 ON delay time
See the parameter '10.05' (DI1 ON delay)
10.09 DI2 OFF delay time
See the parameter '10.06' (DI1 OFF delay)
10.10 DI3 ON delay time
See the parameter '10.05' (DI1 ON delay)
10.11 DI3 OFF delay time
See the parameter '10.06' (DI1 OFF delay)