A1-User’s Manual
109
20.03 Ext1 in source 1
0: Not selected
1: Selected
2: DI1 ----- Initial value
3: DI2
4: DI3
5: DI4
6: DI5
7: DI6
8: DI7
9: DI8
Selects source 1 for parameter
'20.02' (Ext1 commands)
Set 0: Not selected
Always off
Set 1: selected
Always on
Set 2~9 : DI1~ DI8
It works by digital input which is selected
20.04 Ext1 in source 2
See the parameter '20.03' (Ext1 in source 1)
20.05 Ext1 in source 3
See the parameter '20.03' (Ext1 in source 1)
20.06 Ext2 commands
See the parameter '20.02' (Ext1 commands)
20.07 Ext2 in source 1
See the parameter '20.03' (Ext1 in source 1)
20.08 Ext2 in source 2
See the parameter '20.03' (Ext1 in source 1)
20.09 Ext2 in source 3
See the parameter '20.03' (Ext1 in source 1)