A1-User’s Manual
69
8.1.12
Acceleration/Deceleration
No.
Name
Change during
operation
Range
Default
Page
23.03
Ramp set selection
-
0. Acc/Dec Time1
1. Acc/Dec Time2
2. Frequency
3. DI1
4. DI2
5. DI3
6. DI4
7. DI5
8. DI6
9. DI7
10. DI8
0
123
23.04
Acceleration time 1
O
0.0 to 3000 [Sec]
30.0 Sec
124
23.05
Deceleration time 1
O
0.0 to 3000 [Sec]
30.0 Sec
124
23.06
Acceleration time 2
O
0.0 to 3000 [Sec]
30.0 Sec
124
23.07
Deceleration time 2
O
0.0 to 3000 [Sec]
30.0 Sec
125
23.08
Acceleration pattern selection
O
0.
Linear
1.
S Curve
2.
U Curve
0
125
23.09
Deceleration pattern selection
O
0
125
23.10
Acceleration time transition
frequency
O
0.00 to 400.0 [Hz]
0.00 Hz
126
23.11
Deceleration time transition
frequency
O
0.00 to 400.0 [Hz]
0.00 Hz
126
23.12
Jogging acceleration time
O
0.0 to 3000 [Sec]
30.0 Sec
126
23.13
Jogging deceleration time
O
0.0 to 3000 [Sec]
30.0 Sec
126
23.14
Emergency stop time
O
0.0 to 3000 [Sec]
3.0 Sec
126
8.1.13
Speed search
No.
Name
Change during
operation
Range
Default
Page
24.01
Speed search start mode
O
0.
Start from 0 Hz
1.
Start from frequency
corresponding motor speed
0
127
24.03
Voltage increment in speed
search mode
O
10 to 300 [%]
100 %
127