A1-User’s Manual
123
22.34 UP/DOWN ref reset source
0: Not selected ----- Initial value
1: Selected
2: DI1
3: DI2
4: DI3
5: DI4
6; DI5
7: DI6
8: DI7
9: DI8
Selects the source of the UP/DOWN ref reset
It is not works when the up or down source has inputted
Set 0: Not selected
Always off
Set 1: selected
Always on
Set 2~9 : DI1~ DI8
It works by digital input which is selected
UP
reset
Output frequency
UP/DOWN ref
Run command
ON
ON
ON
ON
ON
ON
ON
ON