C N C 4 2 2 0 M a c hi ne Too l Op e ra t ion an d Te st
93
regulation: “3”
Select “0” for line knife
46
System knives
Set the actual knives if turret
knives are used
High level effective: “1”
47
Knife
position
signal level
Low level effective: “0”
High level effective: “1”
48
Knife rack lock
level
Low level effective: “0”
49
Maximum
knife
replacing time
The time that the electric knife
rack rotates one circle (unit:
ms); set according to actual
value
50
Lock delay time
The time from completion of
positive
knife
selection
to
reverse lock delay; please set
accordingly
Knife replacing
control
51
Knife reverse lock
time
The time of the reverse lock of
the turret; please set accordingly
Chuck function on: “1”
52
Chuck
function
effective
control
position
Chuck function off: “0”
Internal chuck continuous output
signal: “0”
External
chuck
continuous
output signal: “1”
Internal chuck pulse output
signal: “2”
53
Chuck mode
External chuck pulse output
signal: “3”
Do not check clamping signal:
“0”
Check clamping signal: “1”
54
Check the chuck
clamping
Check clamping signal and
interlock with main axis: “2”
High level effective: “1”
55
Chuck in position
signal level
Low level effective: “0”
Chuck control
56
Chuck
clamping
time
The time of chuck clamping;
please set accordingly
Tailstock function on: “1”
Tailstock
control
57
Tailstock function
control
Tailstock function off: “0”
Hard limit on: “1”
Hard limit
22
Hard
limit
enabled
Hard limit off: “0”
Only for the
hard limit of
the chip
High level effective: “1”
Hard limit level
23
Hard
limit
effective level
Low level effective: “0”