C N C 4 2 2 0 M a c hi ne Too l Op e ra t ion an d Te st
42
Scanning
A. Select the Auto mode;
B. Press the Program
key to enter the program display interface;
C. Press the address key
;
D. Press the
key to display the next program;
E. Repeat step 3 and 4 to display the saved programs in sequence.
8.1.1
AUTOMATIC RUNNING START
A. Press the Auto
key to enter the auto mode and select desired program;
B. Press the Reset
key and then press the Start
key or external start key to make
the program run automatically.
8.1.2
AUTOMATIC RUNNING STOP
During automatic running, it may be necessary to stop the running of the program due to certain
reasons. This system provides several methods to stop the program.
By instruction (M00)
When the program section that contain M00 is executed, the program stops automatic running,
and saves all mode functions and states. Press the Start key
on the panel or external start key,
the program resumes running.
By keys
A. During automatic running, press the Pause
key or external pause key, and the machine
tool is in the following states:
(1) The machine tool feeding decelerates and stops;
(2) The timing pauses when the G04 instruction executes;
(3) The mode functions and states are saved;
(4) Press the Start
key to resume the running of the program.
B. Press the Reset key
(1) The motion of all axes stops;
(2) The output of M and S function is invalid (may be set in the parameters that whether turn off
main axis positive/negative rotation, lubrication and cooling signals after pressing the Reset key
);
(3) The automatic running stops and the mode function and state maintain.
C. Press emergency stop button
When the machine tool is running, press the emergency stop button (if external emergency
stop signal is valid) if there is any danger or emergency, and the system enters the emergency
stop state immediately. At this moment, the machine tool stops moving immediately, and all
outputs (e.g. main axis rotation, cooling liquid) are turned off. Release the button to relieve the
alarm, and the system enters reset state.
Note 1: Please make sure that the failure has been eliminated before relieving the emergency
stop alarm;
Note 2: Before turning on/off the machine, press the emergency stop button to reduce the