C N C 4 2 2 0 M a c hi ne Too l Op e ra t ion an d Te st
48
10.1.2
SETTINGS IN GRAPH INTERFACE
Press the Setting
key to enter the graph interface, and then press the
or
key
to display the graph parameter interface.
Setting method:
A. In MDI mode, press the
/
key to move the cursor to specified parameters;
B. Type the corresponding value;
C. Press the
key to complete the setting
10.1.3
SYSTEM/DIAGNOSIS PARAMETERS SETTING
Through the parameter setting, you can adjust the characteristics of the drive, machine tool, etc.
Setting method:
A. Turn on the parameter switch in the method described in Chapter 1.1;
B. Select the MDI mode, press the Parameter key
to enter the parameter interface, press
the
/
key to search for the page of required parameters;
C. Press the
/
key to select desired parameter number
D. Input new parameter value;
E. Press the
key to input and display the parameter value;
F. After setting all parameters, please turn off the parameter switch;
The setting method of diagnosis parameters is same to the setting of system parameters.