ADT-09 Series Motion Control Card
62
and at least one minute interval between power-on and power-
off.
◆
Miscellaneous
➢
Do not open housing without permission;
➢
Keep power OFF if not in use for a long time;
➢
Pay close attention to keep dust and ferrous powder away from
control;
➢
Fix freewheel diode on relay coil in parallel if non-solid state
relay is used as output relay. Check whether power supply
meets the requirement to ensure not burning the control.
➢
Install cooling fan if processing field is in high temperature,
due to close relationship between service life of the control
and environmental temperature. Keep proper operative
temperature range for the control: 0
℃
~ 60
℃
.
➢
Avoid using the product in the overheating, humid, dusty, or
corrosive environments;
➢
Add rubber rails as cushion on the place with strong vibration.
◆
Maintenance
Please implement routine inspection and regular check upon the following
items, under the general usage conditions (i.e. environmental condition: daily
average 30
℃
, load rate: 80%, and operating rate: 12 hours/ day)
Routine
Inspection
Routine
● Confirm environmental temperature, humidity, dust,
or foreign objects.
● Confirm abnormal vibration and noise;
● Check whether vents are blocked by yarn etc.
Regular
Check
One year
● Check whether solid components are loose
● Confirm whether terminal block is damaged