![ADT NVR32**-P Series Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/adt/nvr32-p-series/nvr32-p-series_user-manual_2853961091.webp)
Hybrid Standalone NVR User Guide
Event Type
Make your selection from the dropdown: Local Alarm, Net Alarm, IPC Ext Alarm or IPC Offline Alarm.
•
Local Alarm.
The system detects the alarm signal from the alarm input port.
•
Network Alarm.
The system detects the alarm signal from the network.
•
IPC External Alarm.
The system detects the alarm signal from the front-end device and
activates the local NVR.
•
IPC Offline Alarm.
The system generates an alarm when the front-end IPC disconnects from
the local NVR. The alarm can activate a recording, PTZ, snapshot, etc. The alarm lasts until
the IPC and the NVR resume their connection.
Alarm In
Select the channel number from the dropdown, or else select
All
.
Alarm
Enter the Alarm name.
Type
Select the relay type from the dropdown:
Normally Open
or
Normally Closed
.
Period
Click the
Setup
button. The Setup dialog opens.
Figure 3-62
Here you can set the time period when detection is enabled. Select
Sunday to Saturday
from the
dropdown list. Be sure to check the box to the left of the period to enable it. To set your own business
day and non-business days, select work day or non-work day from the drop down list, and then click
the
Setup
button. See Figure 3-63. For example, you can set Monday to Friday as working days and
Saturday and Sunday as non-working days. Click the
Save
button to return to the previous screen.
NVR32xx-P Series User Guide
81