Group 8 — Option 1 Communicate Fire
This option has two settings:
0.
No (Fire Comm disabled).
1.
Yes (Fire Comm enabled).
This option defaults to 1 (Fire Comm enabled).
Group 8 — Option 4 Communicate Set/Unset
This option has two settings:
0.
No (Set/Unset Comm disabled).
1.
Yes (Set/Unset Comm enabled).
This option defaults to 0 (Set/Unset Comm disabled).
Group 8 — Option 6 Communicate Abort
This option has two settings:
0.
No (Abort Comm disabled).
1.
Yes (Abort Comm enabled).
This option defaults to 0 (Abort Comm disabled).
Group 8 — Option 2 Communicate PA Signals (PA and PA Silent)
This option has two settings:
0.
No (PA Comm disabled).
1.
Yes (PA Comm enabled).
This option defaults to 1 (PA Comm enabled).
Group 8 — Option 3 Communicate Intruder
This option has two settings:
0.
No (Intruder Comm disabled).
1.
Yes (Intruder Comm enabled).
This option defaults to 1 (Intruder Comm enabled).
Group 8 — Option 5 Communicate Tamper
This option has two settings:
0.
No (Tamper Comm disabled).
1.
Yes (Tamper Comm enabled).
This option defaults to 0 (Tamper Comm disabled).
Note: Tamper communication is only sent during unset mode. A Tamper during set
(Full, Part or Night) condition, on any zone type, results in an Intruder signal
being sent.