System Programming — Group 7 Comms Options 2 ...................................................... 30
Group 7 — Option 2 Dial Type .............................................................................................. 31
Group 7 — Option 3 Prevent Full Set if Line Fail ................................................................... 31
Group 7 — Option 4 Bell Delay ............................................................................................. 31
Group 7 — Option 5 Push-to-Set .......................................................................................... 32
Group 7 — Option 6 When to Communicate ......................................................................... 32
Group 7 — Option 7 Line Fail ................................................................................................ 32
Group 7 — Option 8 Downloader Options ............................................................................. 33
System Programming – Group 8 Communication Enable / Disable ............................... 33
Group 8 — Option 1 Communicate Fire ................................................................................ 34
Group 8 — Option 2 Communicate PA Signals (PA and PA Silent) ....................................... 34
Group 8 — Option 3 Communicate Intruder .......................................................................... 34
Group 8 — Option 6 Communicate Abort .............................................................................. 34
Group 8 — Option 7 Communicate Verified Alarm ................................................................ 35
Group 8 — Option 8 Communicate Battery Low and AC Mains Failure ................................ 35
Group 8 — Option 9 Communicate Periodic Test Report ...................................................... 35
System Programming — Group 9 Parameters .................................................................. 35
Group 9 — Option 1 Communicate Omitted Zones ............................................................... 36
Group 9 — Option 2 Invert Set/Unset Signals ....................................................................... 36
Group 9 — Option 4 User Omit Zone .................................................................................... 36
Group 9 — Option 5 Restore Signals on Unset or Reset ...................................................... 37
Group 9 — Option 6 Entry Deviation Permitted ..................................................................... 37
Group 9 — Option 7 Print Event Log ..................................................................................... 37
Group 9 — Option 8 Factory Defaults ................................................................................... 37
Group 9 — Option 9 Show Software Version ........................................................................ 38
Group 0 Communications .................................................................................................. 38
Group 0 — Option 1 Technistore Version .............................................................................. 38
Group 0 — Option 2 Verified Alarm Time Window................................................................. 38
Group 0 — Option 3 Assistance Channel .............................................................................. 39
Zone Type Definitions ......................................................................................................... 39
General Information............................................................................................................... 39
0 — Not Used ........................................................................................................................ 39
1 — Final Exit ........................................................................................................................ 39
2 — Keyswitch....................................................................................................................... 40
3 — Intruder .......................................................................................................................... 40
4 — Walk Through ................................................................................................................ 40
5 — 24 Hour Tamper ............................................................................................................. 40
6 — PA Silent ........................................................................................................................ 40
8 — Push-to-Set .................................................................................................................... 41
9 — Fire ................................................................................................................................ 41
iii
Содержание ACCORD XPC
Страница 1: ...Installation Manual ...
Страница 2: ......
Страница 12: ...6 ...
Страница 48: ...42 ...
Страница 56: ...50 ...
Страница 61: ...55 Accord xpC July 2001 ...
Страница 62: ...56 IE1 1230 63 Issue D ...