User’s Manual
Callback Center Setup by LAN connections
Highlight the box beside
IP Address
and enter the IP address of the computer you want
contacted during an event.
Highlight the box beside
Retry
and enter the number of times you would like the DVR to try
contacting the computer. You can select from 1 to 10 retrys.
Callback Center Setup by Modem connections
Highlight the box beside Device and press the
button. Select
Internal Modem
,
External
Modem
or
None
from a drop-down menu.
Highlight the box beside
Pager Number
and enter the telephone number of the pager. Enter
the number as it must be dialed from your telephone system; e.g., if you must dial “9” for an
outside line, enter “9” before the pager number.
Highlight the box beside
Mailbox
and enter the voice mailbox number if your pager uses a
voice mailbox.
Highlight the box beside
Site ID
and enter a three-digit site ID number.
When an event occurs, the DVR will dial the pager and leave a four-digit number. The first
three digits are the site ID number and the last digit is the type of event (1: Alarm In, 2: Motion
Detection, 3: Video Loss and 10: Storage). For example, “0753” means that Site 75 has lost
video.
NOTE: The DVR will wait for at least four minutes between pages. If another event
occurs less than four minute after the DVR has notified a pager, it will not dial the pager.
It does this so that the telephone line will not be tied up.
You can save your changes by highlighting
OK
and pressing the
button. Selecting
Cancel
exits the screen without saving the changes.
Password Setup Screen
An Administrator password is required to turn the system off, enter the setup screen, load
default setups, clear all data, change system date and time and change the Administrator
password. A User password is required to enter playback, fast forward playback and fast
backward playback modes from live monitoring mode, enter the search menu screen in live
monitoring mode, and press the
ALARM
button to display the event log in live monitoring mode
unless there is an active alarm. Highlight
Password
in the Main menu and press to enter the
Password
screen.
58