background image

ADJ Products, LLC  -  www.adj.com  - Vizi Beam Hybrid 2R Instruction Manual Page 18

Slave Mode - This function lets you designate the unit as the slave in 

a Master-Slave configuration.

1. Access the main menu, and press the UP or DOWN buttons so 

that “Function” is highlighted, then press ENTER.
2. Press the UP or DOWN buttons until “Slave Mode” is displayed, 

and press ENTER.
3. Either Slave 1, Slave 2, or Slave 3 will be displayed. Press ENTER 

to select either of the three, or press MODE/ESC button to exit.

Auto Program - This function allows the internal programs to run in 

either stand-alone or master/slave mode. In “Master” mode the fix-

ture will send DMX data to other fixtures connect via the DMX chain. 

In “Alone” mode the fixture will operate as a single fixture. The pro-

gram for this mode is selected in the “Select program” section of

the control menu. You can set the number of steps under “Edit pro-

gram”. You can edit the individual scenes under “Edit scenes”. With 

this function, you can run the individual scenes either automatically, 

i.e. with the adjusted Step-Time.
1. Access the main menu, and press the UP or DOWN buttons so 

that “Function” is highlighted, then press ENTER.
2. Press the UP or DOWN buttons until “Auto Program” is displayed, 

and press ENTER.
3. Either “Master” or “Alone” will be displayed.
4. Press ENTER to to make your selection, or press MODE/ESC 

button to exit.

Sound Control - With this function, the internal program will run in 

sound active mode.
1. Access the main menu, and press the UP or DOWN buttons so 

that “Function” is highlighted, then press ENTER.
2. Press the UP or DOWN buttons until “Sound Control” is dis-

played, press ENTER.
3. Either “Master” or “Alone” will be displayed. Use the UP or DOWN 

buttons to change the operating mode.

  Vizi Beam Hybrid 2R 

 

 

 

 System Menu

ADJ Products, LLC  -  www.adj.com  - Vizi Beam Hybrid 2R Instruction Manual Page 41

  Vizi Beam Hybrid 2R 

 

                           Operation

      DOWN buttons select “Alone” and press ENTER.

 

Master-Slave Operation (Sound Active or Auto Program): 

This function will allow you to link up to 16 units together and oper-

ate without a controller. The units can run a built-in program or run in 

sound actiive mode. In Master-Slave operation one unit will act as the 

controlling unit and the others will react to the controlling units pro-

grams. Any unit can act as a Master or as a Slave.

1.   Using standard XLR microphone cables, daisy chain your units  

  together via the XLR connector on the rear of the units. Remem- 

  ber the Male XLR connector is the input and the Female XLR    

  connector is the output. The first unit in the chain (master) will use  

  the female XLR connector only - The last unit in the chain will use  

  the male XLR connector only. For longer cable runs we suggest a  

  terminator at the last fixture.

2.   On your “Master” unit, access the main menu, and press the UP 

      or DOWN buttons so that “Function” is highlighted, then  

       

      press ENTER.

3.   Select your desired operating mode. Use the UP or DOWN but- 

      tons to select between “Auto Program” or “Sound Control”,    

      press ENTER to select your desired program.

4.   Either “Master” or “Alone” will be displayed. Using the UP or     

      DOWN buttons select “Master” and press ENTER.

5.   For your “Slave” units, access the main menu, and press the UP 

      or DOWN buttons so that “Function” is highlighted, then  

       

      press ENTER.

6.   Press the UP or DOWN buttons until “Slave Mode” is displayed,  

      and press ENTER.

7.   Either Slave 1, Slave 2, or Slave 3 will be displayed. Select your  

      desired Slave setting and press ENTER.

5.   Press MODE/ESC if you want to return to the main menu.

6.   You may change the show or invert the pan and tilt functions           

   in the system menu by following the directions on pages 26-27.

Содержание Vizi Beam Hybrid 2R

Страница 1: ...LLC 6122 S Eastern Ave Los Angeles CA 90040 USA Tel 323 582 2650 Fax 323 725 6100 Web www adj com E mail info americandj com A D J Supply Europe B V Junostraat 2 6468 EW Kerkrade Netherlands service a...

Страница 2: ...nd direct or indirect economic loss associated with the use or reliance of any information contained within this document and or as a result of the improper unsafe unsufficient and negligent as sembly...

Страница 3: ...ion 6 Important Discharge Lamp Warnings 7 Mounting 8 Controls and Functions 10 DMX Set Up 13 System Menu 16 Error Codes 38 Operation 40 DMX Traits 42 Lamp Replacement 54 Fuse Replacement 54 Cleaning 5...

Страница 4: ...n shipping charges only to a designated point within the United States If the entire instrument is sent it must be shipped in it s original package No accessories should be shipped with the product If...

Страница 5: ...fied service personnel when A Objects have fallen or liquid has been spilled into the appliance B The appliance has been exposed to rain or water C The appliance does not appear to operate normally or...

Страница 6: ...sure not to confuse the spare fuse with active fuse Vizi Beam Hybrid 2R Lamp Replacement Caution Always replace with the exact same type lamp and fuse unless otherwise specified by an authorized ADJ...

Страница 7: ...this manual with the unit for future reference Vizi Beam Hybrid 2R General Instructions Caution There are no user serviceable parts inside this unit Do not attempt any repairs yourself doing so will v...

Страница 8: ...lamp explosion which could lead to hot glass particles falling from the fix ture Failure to change the lamp within 300 hours of operation will result in automatic shut down of the fixture s electroni...

Страница 9: ...g removing or servicing the unit Overhead mounting requires extensive experience including calculat ing working load limits installation material being used and perodic safety inspection of all instal...

Страница 10: ...the temperatures stated above This will allow the fixture to run at its best and help prolong the fixture life ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 9 ADJ Products L...

Страница 11: ...S 0 19 COLOR CHANGE NORMAL 20 29 COLOR CHANGE TO ANY POSITION 30 39 COLOR GOBO CHANGE TO ANY POSITION 40 59 LAMP ON 60 79 LAMP OFF 80 84 ALL MOTOR RESET 85 87 SCAN MOTOR RESET 88 90 COLOR MOTOR RESET...

Страница 12: ...oving head may severely damage the unit and will void the unit warranty 11 Lamp Assembly and Access Plate This plate accesses the lamp socket assembly The unit includes a spring mounted discharge lamp...

Страница 13: ...5 amp protective fuse Never defeat the fuse the fuse is designed to protect the electronics in the event of severe power fluctuations Always be sure to replace the fuse with an exact match as the one...

Страница 14: ...s of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain Data Cable DMX Cable Requirements For DMX and Master Slave Operation The...

Страница 15: ...or which is con nected between pins 2 and 3 of a male XLR connector DATA and DATA This unit is inserted in the female XLR connector of the last unit in your daisy chain to terminate the line Using a c...

Страница 16: ...Hybrid 2R Set Up ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 44 Vizi Beam Hybrid 2R 10 Channel DMX Mode Channel Value Function 5 PRISM GOBO MACROS 208 215 MACRO 11 216 22...

Страница 17: ...ee Key Lock Temperature C F Celsius Fahrenheit Temperature switch between Initial Status PAN XXX Initial effect position Reset Default ON OFF Restore factory set Reset Function Reset All Reset Pan Til...

Страница 18: ...s function will allow you to see the DMX value of each DMX channel that is currently being used at the time 1 Access the main menu and press the UP or DOWN buttons so that Function is highlighted then...

Страница 19: ...to change the operating mode Vizi Beam Hybrid 2R System Menu ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 41 Vizi Beam Hybrid 2R Operation DOWN buttons select Alone and pr...

Страница 20: ...Elation Show Designer to control head movement the color wheel gobo wheel prism master dimmer shutter strobe and vari ous other features A DMX controller allows you to create unique pro grams tailore...

Страница 21: ...ess ENTER or press MODE ESC to exit Lamp Off Time This will allow you to check the running time of the lamp the last time that the lamp was On 1 Press the MODE ESC button to access the main menu Press...

Страница 22: ...ode brings all the internal motors to a home position If there is an internal problem with one or more of the motors an error code will flash in the display in the form of XXer XX will represent a fun...

Страница 23: ...ection or press MODE ESC to exit Temperature Info This will allow you to check the moving head temperature 1 Press the MODE ESC button to access the main menu Press the UP or DOWN buttons so that Info...

Страница 24: ...o access the main menu Press the UP or DOWN buttons so that Lamp Control is highlighted then ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 36 Vizi Beam Hybrid 2R System Menu...

Страница 25: ...press ENTER 2 Press the UP or DOWN buttons until Lamp Off Via DMX is dis played press ENTER 3 Either Off or On will be displayed use the UP and DOWN but ADJ Products LLC www adj com Vizi Beam Hybrid 2...

Страница 26: ...p is higher then the preset value for longer then 5 mins the unit will automatically shut Off the lamp If the lamp is automatically shut off due to over heat it can not be restriked automatically it m...

Страница 27: ...o toggle between 5 Press ENTER to confirm your selection or press MODE ESC to exit Pan Reverse With this function you can reverse the Pan movement Vizi Beam Hybrid 2R System Menu ADJ Products LLC www...

Страница 28: ...s dis played press ENTER 3 Press UP or DOWN buttons until Pan Degree is displayed and press ENTER ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 32 Vizi Beam Hybrid 2R System...

Страница 29: ...ER to confirm your selection or press MODE ESC to exit ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 31 Vizi Beam Hybrid 2R System Menu 2 Press the UP or DOWN buttons until...

Страница 30: ...n press ENTER Vizi Beam Hybrid 2R System Menu ADJ Products LLC www adj com Vizi Beam Hybrid 2R Instruction Manual Page 29 Mic Sensitivity With this function you can set the microphone sensitivity The...