Example of possible configurations:
Desired case (except 100% event)
Associated
configuration
Theoretical number
of periodic frames
sent per day
• Reading/ Poll: 10 minutes
• Backup: every hour (every 6 readings)
• Sending: every half day (every 12 backups)
• 321 = 300
• 320 = 6
• 301 = 12
2 frames
• Reading/ Poll: 10 minutes
• Backup: at each reading
• Sending: maximum tolerated by my frame (here, WMBus)
• 321 = 300
• 320 = 1
• 301 = 15
9 or 10 frames
• Reading/ Poll: 5 minutes
• Backup: every 15 minutes (every 3 readings)
• Sending: every hour (i.e., every 4 backups)
• 321 = 150
• 320 = 3
• 301 = 4
24 frames
• Poll/Sending: every hour
• Backup: at each reading
• Sending: at each backup
• 321 = 1800
• 320 = 1
• 301 = 1
24 frames
• Poll/Sending: every hour
• Backup: at each reading
• Sending: every 4 hours (every 4 backups)
• 321 = 1800
• 320 = 1
• 301 = 4
6 frames
• Poll/Sending: every 10 seconds
• Backup: every minute (every 6 readings)
• Sending: every quarter hour (every 15 backups)
• 321 = 5
• 320 = 6
• 301 = 15
96 frames
• Poll/Sending: every hour
• Backup: at each reading
• Sending: every 10 minutes (every 10 backups)
• 321 = 30
• 320 = 1
• 301 = 10
144 frames